MAINTENANCE
•Use a vacuum cleaner to pick up loose dirt and debris.
CAUTION
Improper treatment of generator can damage it and shorten its life.
•DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
•DO NOT insert any objects through cooling slots.
ENGINE MAINTENANCE
WARNING
Unintentional sparking can result in fire or electric shock.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
•Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
•Use approved spark plug tester.
•DO NOT check for spark with spark plug removed.
Oil
Oil Recommendations
NOTE: When adding oil to the engine crankcase, use only high quality detergent oil classified “For Service SF, SG, SH, SJ” or higher. DO NOT use special additives.
1.Choose a viscosity according to the following table:
NOTE: Synthetic oil meeting ILSAC
SAE 30: 40 °F and higher (5 °C and higher) is good for all purpose use above 40°F, use below 40°F will cause hard starting.
*Check oil level frequently at higher temperatures.
Synthetic
Checking Oil Level
Oil level should be checked prior to each use or at least every 5 hours of operation. Keep oil level maintained.
1.Make sure generator is on a level surface.
2.Clean area around oil fill and remove oil fill cap.
3.Verify oil is at the point of overflowing at oil fill opening.
4.Replace and tighten oil fill cap.
Adding Engine Oil
1.Make sure generator is on a level surface.
2.Check oil level as described in “Checking Oil Level”.
3.If needed, slowly pour oil into oil fill opening to the point of overflowing at oil fill.
4.Replace and tighten oil fill cap.
Servicing Air Cleaner
Your engine will not run properly and may be damaged if you run it with a dirty air cleaner.
Replace the air cleaner every 25 hours of operation or once each year, whichever comes first. Replace more often if operating under dirty or dusty conditions.