BSPP Generator

120 Volt AC, 30 Amp Locking Receptacle

Use a NEMA L5-30 plug with this receptacle. Connect a

3-wire cord set rated for 125 Volts AC at 30 Amps to the plug (Figure 11).

Figure 11 — 120 Volt AC, 30 Amp, Locking Receptacle

3-Wire Cord Set

NEMA L5-30

Neutral

120V

Hot

Ground (Green)

Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3,600 watts (3.6 kW) of power at 30 Amps.The outlet is protected against overload by a push–to–reset circuit breaker and/or a 2 pole GFCI circuit breaker.

120 Volt AC, 20 Amp, Duplex Receptacle

Each duplex receptacle (Figure 12) is protected against overload by a push–to–reset circuit breaker and/or a 2 pole GFCI circuit breaker.

Figure 12 — 120 Volt AC, 20 Amp, Duplex Receptacle

Use each receptacle to operate 120 Volt AC, single–phase, 60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater).

12 Volt DC, 10 Amp Receptacle

This receptacle (Figure 13) allows you to recharge a 12 Volt automotive or utility style storage battery.

Figure 13 — 12 Volt DC, 10 Amp Receptacle

This receptacle can not recharge 6 Volt batteries and can not be used to crank an engine having a discharged battery. See “Charging a Battery” on page 10 before attempting to recharge a battery.This outlet is protected by a 10 Amp self resetting circuit breaker.

12

Page 12
Image 12
Briggs & Stratton PRO8000 01934 owner manual Volt AC, 30 Amp Locking Receptacle, Volt AC, 20 Amp, Duplex Receptacle