LIGHTING THE SIDE BURNER:

1.Open lid before lighting side burner.

2.Make sure control knob is in the "OFF" position.

3.Push and turn side burner control knob to the "HIGH" position.

4.Press the electronic igniter on the main control panel and hold for 3–5 seconds to light burner.

5. If ignition does NOT occur in 5 seconds, turn control knob to "OFF", wait 5 minutes to allow gas to dissipate and repeat lighting procedure.

6. To turn off, turn each control knob clockwise until it locks in the "OFF" position.

NOTE: If burner does not light or flame is too low, you may have spider or other insect blockage in burner, or the flow limiting device has been activated. See "Burner Assembly/Maintenance" under Proper Care and Maintenance, or "Regulator Resetting Procedure" under Connecting LP Cylinder and Hose/Regulator to Grill.

MATCH LIGHTING THE SIDE BURNER:

1.Open the lid to the side burner before lighting.

2.Turn the burner control knob to "OFF”.

3.Strike and carefully place a match approximately 1/2" (1 to 2 cm) from the burner.

4.Turn the side burner control knob to the "HIGH" position. The burner should light within 5 seconds.

5.If the burner does not light, turn the control knob to "OFF" and wait 5 minutes for gas to dissipate and repeat lighting procedure.

6.If the burner does not light within the first few attempts of match lighting, there is a problem with the gas supply. Turn off the gas at the burner and cylinder. DO NOT attempt to operate the grill until the problem is found and corrected. See "Trouble Shooting" section of this manual.

NOTE: Observe flame height when lit: Flame should be a Blue/Yellow color between 1"–2" when burner is on "HIGH”.

TURNING OFF THE GRILL:

1.Turn off the cylinder valve.

2.Turn all burner control knobs to the "OFF" position.

NOTE: Turn off LP cylinder first to prevent gas from being left in the system under pressure.

CAUTION!

The cylinder valve should always be in the off, or closed, position when the grill is not in use.

To turn off the cylinder valve, turn knob clockwise until it stops.

IMPOR

TA

NT

 

 

DO NOT

 

 

TURN

REMOVESAFEGU

USINGVALVETANK.

ONAND

 

GAS ON THIS TAGARD

FLAMECONTROLUSE THISL.P.OFF￿

 

 

VALVE REDGAS￿ ￿

 

ADJUSTMENTFOR ￿

 

 

 

 

ONLY.

11

Page 12
Image 12
Brinkmann Series 2210 owner manual Match Lighting the Side Burner, Turning OFF the Grill

Series 2210 specifications

The Brinkmann Series 2210 is a sophisticated, high-performance scientific instrument designed for various analytical applications in laboratories. Renowned for its precision and reliability, the Series 2210 is engineered to meet the demands of modern research and quality control processes.

One of the standout features of the Brinkmann Series 2210 is its advanced measurement capabilities. Equipped with innovative sensors and cutting-edge technology, the device offers precise measurements across a wide range of parameters. Whether it is pH, conductivity, or ion concentration, the Series 2210 delivers accurate results, which are critical for laboratory analysis.

The user-friendly interface greatly enhances the overall experience. The device features an intuitive display that allows users to navigate through various functions and settings with ease. This ensures that even those with minimal technical expertise can operate the instrument effectively, making it accessible for a wide range of users.

Incorporating robust data management features, the Brinkmann Series 2210 allows for seamless data logging and storage. It can be connected to computers or laboratory management systems via USB or other connectivity options, facilitating easy data transfer and analysis. This feature is particularly beneficial for laboratories that require consistent record-keeping for compliance and reporting purposes.

Another key characteristic of the Series 2210 is its durability and build quality. Constructed with high-grade materials, it is designed to withstand the rigors of daily laboratory use while maintaining accuracy and reliability over time. This ruggedness ensures that it is a worthwhile investment for any laboratory looking to enhance its analytical capabilities.

The Brinkmann Series 2210 also embraces modern technological advancements by offering optional wireless connectivity. This feature enables remote monitoring and control, allowing users to access live data from mobile devices or computers. Such flexibility is vital for laboratories that prioritize efficiency and real-time analysis.

In summary, the Brinkmann Series 2210 stands out in the crowded field of analytical instruments due to its precision, user-friendly interface, robust data management capabilities, and durable construction. Whether for routine quality checks or advanced research applications, the Series 2210 continues to set a benchmark for reliability and performance in laboratory environments. Its commitment to innovation and excellence makes it a trusted choice for scientists and researchers worldwide.