WARNING

FOR OUTDOOR USE ONLY. DO NOT operate indoors or in an enclosed area such as a garage, shed or breezeway.

Use your grill OUTDOORS in a well ventilated space away from dwellings or other buildings to prevent dangers associated with gas accumulation and toxic vapors. We recommend your grill be situated at least 10 feet (3.1 m) from buildings.

Maintain a minimum clearance of 36 inches (91 cm) between all sides of grill and walls or other combustible material. DO NOT use grill under overhead unprotected combustible construction.

DO NOT use or install this grill in or on a recreational vehicle and/or boat.

INSTALLATION INFORMATION:

The installation of this appliance must be in accordance with:

All applicable local codes, or in the absence of local codes, either:

National Fuel Gas Code ANSI Z223.1 NFPA 54

Natural Gas and Propane Installation Code: CAN/CGA B149.1

Natural Gas Installation Code: CAN/CGA B149.1 (Canada)

Propane Installation Code: CAN/CGA B149.2 (Canada)

To check your local codes, see your local LP gas dealer or natural gas company. This grill was not intended to be connected to a natural gas supply line. If an external electrical source is utilized, it must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA 22.1.

WARNING

LP GAS CYLINDER (NOT SUPPLIED WITH THIS GRILL)

The LP cylinder is available for purchase at the same location the grill was purchased.

The LP (Liquid Propane) gas cylinder specifically designed to be used with this grill must have a 20 lb. (9.1 kg) capacity incorporating a Type 1 cylinder valve and an over-filling protection device (OPD).

DO NOT connect this grill to an existing #510 POL cylinder valve with Left Hand threads. The Type 1 valve can be identified with the large external threads on the valve outlet.

DO NOT connect to a propane cylinder exceeding this capacity.

DO NOT connect to a cylinder that uses any other type of valve connection device.

4

Page 5
Image 5
Brinkmann Series 2210 owner manual Installation Information, LP GAS Cylinder not Supplied with this Grill

Series 2210 specifications

The Brinkmann Series 2210 is a sophisticated, high-performance scientific instrument designed for various analytical applications in laboratories. Renowned for its precision and reliability, the Series 2210 is engineered to meet the demands of modern research and quality control processes.

One of the standout features of the Brinkmann Series 2210 is its advanced measurement capabilities. Equipped with innovative sensors and cutting-edge technology, the device offers precise measurements across a wide range of parameters. Whether it is pH, conductivity, or ion concentration, the Series 2210 delivers accurate results, which are critical for laboratory analysis.

The user-friendly interface greatly enhances the overall experience. The device features an intuitive display that allows users to navigate through various functions and settings with ease. This ensures that even those with minimal technical expertise can operate the instrument effectively, making it accessible for a wide range of users.

Incorporating robust data management features, the Brinkmann Series 2210 allows for seamless data logging and storage. It can be connected to computers or laboratory management systems via USB or other connectivity options, facilitating easy data transfer and analysis. This feature is particularly beneficial for laboratories that require consistent record-keeping for compliance and reporting purposes.

Another key characteristic of the Series 2210 is its durability and build quality. Constructed with high-grade materials, it is designed to withstand the rigors of daily laboratory use while maintaining accuracy and reliability over time. This ruggedness ensures that it is a worthwhile investment for any laboratory looking to enhance its analytical capabilities.

The Brinkmann Series 2210 also embraces modern technological advancements by offering optional wireless connectivity. This feature enables remote monitoring and control, allowing users to access live data from mobile devices or computers. Such flexibility is vital for laboratories that prioritize efficiency and real-time analysis.

In summary, the Brinkmann Series 2210 stands out in the crowded field of analytical instruments due to its precision, user-friendly interface, robust data management capabilities, and durable construction. Whether for routine quality checks or advanced research applications, the Series 2210 continues to set a benchmark for reliability and performance in laboratory environments. Its commitment to innovation and excellence makes it a trusted choice for scientists and researchers worldwide.