In a series of interconnected Alarms, you must test each Alarm separately by pressing and holding the test button. Make sure all units alarm when each one is tested.

If any unit in the series does not alarm during testing, TURN OFF POWER and recheck connections. If it does not alarm when you restore power, replace it immediately.

ACTIVATING THE BATTERY BACK-UP

Activate the battery back-up by remov- ing the “Pull to Activate Battery Back- Up” tab. You do not need to open the battery compartment and reposition

the battery during installation.

DO NOT remove the battery activation tab until AC power is turned on to conserve battery power.

Test the alarm. Press and hold the test button on the cover until the alarm sounds:

4 beeps, pause, 4 beeps, pause.

CHAPTER 3: IF YOUR CO ALARM SOUNDS

Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. When your CO Alarm sounds, you must not ignore it!

IF THE ALARM SOUNDS:

1.Operate the Test/Silence button to silence the alarm.

2.Call your emergency services, fire department or 911. Write down the number of your local emergency service here:

________________________________________

3.Immediately move (everyone) to fresh air—out- doors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re-enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.

(Do not remove or disconnect the alarm!)

4.After following steps 1-3, if your CO Alarm reacti- vates within a 24-hour period, repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are iden- tified during this inspection have the equipment serviced immediately. Note any combustion equip- ment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operat- ing in an attached garage or adjacent to the resi- dence. Write down the number of a qualified appli- ance technician here:

_______________________________________

17

Page 19
Image 19
BRK electronic CO5120PDB user manual If the Alarm Sounds, Do not remove or disconnect the alarm

CO5120PDB specifications

The BRK electronic CO5120PDB is a state-of-the-art combination carbon monoxide and smoke detector that offers enhanced safety features for modern homes. Designed with innovation in mind, this device aims to provide reliable protection against the dangers of carbon monoxide poisoning and smoke inhalation from fires.

One of the standout features of the CO5120PDB is its dual-sensor technology. It incorporates both photoelectric and ionization sensors. The photoelectric sensor is highly effective in detecting slow-burning fires that produce a lot of smoke, while the ionization sensor is adept at detecting fast-flaming fires. This combination ensures comprehensive smoke detection, providing a higher level of safety and peace of mind for homeowners.

In addition to its advanced smoke detection capabilities, the CO5120PDB is equipped with a highly sensitive carbon monoxide sensor. Carbon monoxide is an insidious gas that cannot be seen or smelled, making it a silent threat in many households. The CO sensor can quickly identify dangerous levels of this gas, sounding an alarm to alert residents and help them take necessary action.

The CO5120PDB features a user-friendly design, including a digital display that shows the current CO levels in parts per million (ppm). This allows users to monitor the levels of carbon monoxide in real time. The detector also comes with a voice alert feature, providing clear and understandable warnings in the event of smoke or CO detection, which helps in identifying the situation promptly.

Another significant characteristic of the CO5120PDB is its ability to operate even during power outages. It is equipped with a battery backup system that ensures continuous operation, making it ideal for locations where power interruptions may occur. Additionally, the device has a test/silence button that allows users to test the unit for functionality as well as silence false alarms if necessary.

Installation is straightforward with the CO5120PDB, which can be mounted on walls or ceilings, adhering to the recommendations of safety organizations regarding placement. The unit also features a sleek design that blends seamlessly into home decor, ensuring that safety doesn’t compromise aesthetics.

In conclusion, the BRK electronic CO5120PDB is an exemplary choice for those seeking robust protection against both carbon monoxide and smoke. Its dual-sensor technology, digital display, voice alerts, and battery backup make it an indispensable addition to any household, ensuring that residents can live with comfort and peace of mind, knowing they are protected from two of the most significant indoor hazards.