BRK electronic CO5120PDB What You See and Hear Under Different Conditions continued, Horn, Power

Models: CO5120PDB

1 30
Download 30 pages 34.1 Kb
Page 5
Image 5
What You See and Hear Under Different

What You See and Hear Under Different

Conditions (continued)...

If battery becomes low or is missing

Horn

Chirps once

 

a minute*

 

 

Display

The word “bat”

 

flashes on and off

 

 

POWER/

Flashes once a

ALARM Light

minute

*Note: If the battery becomes very weak, you will hear extra “chirps.” Replace the battery immediately!

Disconnect AC power before changing battery. Shock hazard exists if AC power is miswired.

If the CO alarm is not operating properly

Horn

Three rapid chirps

 

every minute

 

 

Display

Displays “Err”

 

 

POWER/

Flashes three

ALARM Light times in sync with the horn

WHAT YOU SEE AND HEAR IF CO IS DETECTED Pre-Alarm Levels

Horn

Silent

Display

Shows CO levels

 

detected in ppm

POWER/

Shines

ALARM Light

continuously

Alarm levels of CO are detected (Over 70 ppm)

Horn

Sounds loudly -

 

4 beeps, pause,

 

4 beeps, pause.

 

This sequence

 

repeats for as

 

long as the unit

 

is in alarm*

Display

Shows CO levels

 

detected in ppm

POWER/

Flashes once

ALARM Light

per second

*Note: If unit goes into alarm under battery back-up power, the regular 4 beeps-brief pause cycle will repeat for four minutes. After four minutes, the pause will increase to 1 minute.

Continued)...

3

Page 5
Image 5