INSTALLATION, Continued
See “Avoiding Dead Air Spaces” for more information.
NOTE: For any location, make sure no door or other obstruction could keep carbon monoxide or gas from reaching the Alarm.
This unit should receive continuous electrical power. (The battery is meant for emergency
WHERE THIS ALARM SHOULD NOT BE INSTALLED
To avoid causing damage to the unit, to provide optimum protection, and to prevent unnecessary alarms, Do NOT locate this Alarm:
•In garages, kitchens, crawl spaces and unfinished attics. Avoid extremely dusty, dirty or greasy areas. Installation in these areas could lead to nuisance alarms, may expose the sensor to substances that could damage or contaminate it, or the Alarm may not be heard by persons in other areas of the home, especially if they are sleeping.
•In the garage, vehicle exhaust can contain some carbon monoxide. These levels are higher when the engine is first started. Within hours of starting a vehicle and backing it out of the garage, the levels present over time can activate the Alarm and become a nuisance.
•In the kitchen, some gas appliances can emit a short burst of CO or gas upon
•Keep units at least 20 feet (6 meters) from the sources of combustion particles (stove, furnace, water heater, space heater) if possible. In areas where a
Alarm near a cooking or heating appliance, install at least 5 feet (1.5 meters) from appliance.
•In extremely humid areas. This Alarm should be at least 10 feet (3 meters) from a shower, sauna, humidifier, vaporizer, dishwasher, laundry room, utility room, or other source of high humidity.
•In direct sunlight.
•In turbulent air, like near ceiling fans or open windows. Blowing air may prevent CO or gas from reaching the sensors.
•In areas where temperature is colder than 40˚ F (4˚ C) or hotter than 100˚ F (38˚ C). These areas include
•Less than 12 inches (305 mm) away from fluorescent lights. Electrical “noise” can interfere with the sensor.
•In “dead air” spaces. See “Avoiding Dead Air Spaces”.
AVOIDING DEAD AIR SPACES
“Dead air” spaces may prevent gas from reaching the Alarm. To avoid dead air spaces, follow installation recommendations below.
On ceilings, install Alarms as close to the center of the ceiling as possible.
If this is not possible, install the Alarm at least 4 inches (102 mm) from the wall or corner.
For wall mounting, the top edge of Alarms should be placed between 6 inches (152 mm) and 12 inches (305 mm) from the wall/ceiling line.
On a peaked, gabled, or cathedral ceiling, install Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured horizontally.
BEFORE YOU BEGIN INSTALLATION
Since CO generally mixes well with air, mounting the Alarm will depend on the type of explosive gas you intend to detect. If you are not certain which type of gas you are using in your home, please read about natural gas and propane in “Where to Install this Alarm”.
•Make sure the alarm is not receiving excessively noisy power. Examples of noisy power could be major appliances on the same circuit, power from a generator or solar power, light dimmer on the same circuit or mounted near fluorescent lighting. Excessively noisy power may cause damage to your Alarm.
Find the pair of
•On each label write in the phone number of your emergency responder (like 911) and a qualified appliance technician.
•Place one label near the Gas/CO Alarm, and the other label in the “fresh air” location you plan to go if the alarm sounds.
HOW TO INSTALL THIS GAS/CO ALARM
IMPORTANT! Read all instructions before using this product. Tools you will need: Screwdriver, drill.
1.Determine the best location for your Gas/CO Alarm.
2.Your Alarm is equipped to be mounted as a corded unit (recommended for natural gas detection), a direct plug unit (recommended for propane gas detection). The unit can be plugged directly into a wall outlet. If your outlets are mounted horizontally, refer to “If Outlet is Mounted Horizontally (Sideways)”.
If the adapter is taken out of the unit, the Alarm can be installed high on the wall, while the adapter is plugged into a wall outlet. The explosive gas you use will determine if the Alarm should be installed high on the wall (AC cord option) or low on the wall (direct plug option).
ACTIVATING THE BATTERY BACK-UP
Activate the battery
The Alarm will
DIRECT PLUG ALARM INTO AN OUTLET (for Propane Detection)
This Alarm can be plugged directly into a wall outlet located close to the floor. This is the recommended configuration for detecting propane.
1.Choose a standard UNSWITCHED 120V AC outlet.
2.Plug Alarm in.
IF OUTLET IS MOUNTED HORIZONTALLY (SIDEWAYS)
If you are going to use your Alarm as a direct plug into an outlet that is mounted horizontally (sideways), you may want to rotate the adapter 90º, as follows:
1.With back of unit facing you (AC blades on your left), place your left thumb on adapter release and grab AC blades with your right hand to release the left side.
2.Repeat for the other side adapter thumb release. This will allow adapter to slide out.
3.Remove adapter.
4.Rotate the adapter 90º and snap firmly back into place.
5.Plug Alarm into AC outlet.
WALL MOUNTED ALARM (for Natural Gas Detection)
Installation tips for power cord models: The power cord option provides more flexibility in mounting locations and allows the Alarm to be easily installed at or above eye level.
NOTE: If you mount the Alarm high on a wall, make sure it is between 6 to 12 inches
NOTE: Do not cover the Alarm with a curtain.
To install for a
1.Repeat steps 1 to 3 as described above in “to rotate the adapter”.
2.With adapter out, pull out power cord and unwrap it.
3.Insert the screws provided until head is approx. 1/8 inch (3 mm) from wall (if mounting in plaster board or drywall, drill 3/16 inch (5 mm) hole and use plastic anchor provided). Use mounting guide template to locate holes as shown in diagram below.
4.Hook the Alarm over the screw onto the keyhole in back of unit.
5.Plug power cord into AC outlet.
SECURING THE POWER CORD TO AN OUTLET
DISCONNECT POWER TO THE OUTLET TO AVOID ELECTRICAL SHOCK.
1.Remove the wallplate screw from the outlet and hold the wallplate in position.
2.Plug the power cord into the wall outlet so that the screw hole lines up with the wallplate screw hole.
3.Insert the screw through the power cord screw hole and into the wallplate screw hole.
4.Tighten screw in place and restore power to the outlet.
Mounting Guide Template
3 7/83.875inchesinches(98mm)
2