MOTOR

Before motor is removed, it should be tested to be sure it is inoperative. Check the continuity of the motor.

CHECK CONTINUITY

 

Black to Orange

If open, replace motor

Red to Orange

If open, replace motor

Gray to Orange

If open, replace motor

Green to Motor Frame

If open, inspect wire to

 

be sure it is properly

 

attached to motor

 

frame

1.Lower ram manually until there is approximately 7" between the bottom assembly and the ram.

2.Disconnect molex connector from motor to wire harness.

3.Using a 3/8" nut driver or socket, remove the four nuts hold- ing the motor to the gearbox. Remove air scentry tray and pull motor out through front of compactor.

4.Install motor in reverse procedure.

BLACK GRAY

RED GREEN

ORANGE

EMERSON MOTOR

93030201

CENTRIFUGAL SWITCH

(USED ON EMERSON MOTOR)

BROWN

 

 

 

 

 

 

YELLOW

 

 

 

 

WHITE

 

 

 

 

BLUE

 

 

 

 

 

 

 

 

WIRING SCHEMATIC

 

SCHEMATIC SHOWS UNIT AT END

 

L1

R

OF CYCLE - IN TOP POSITION

 

 

 

 

 

DRAWER OPEN

 

 

 

TR

OFF-ON

 

 

 

 

BK

V

 

 

BK (or BR)

 

 

 

 

 

 

 

 

 

 

 

START

 

 

 

C

NC

Y

 

 

 

BL/W

 

 

 

C

 

 

 

 

 

BL

NO

BL/W

 

 

NO

KEY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

NC

 

 

C

 

 

 

 

Y

 

NC

 

 

 

 

 

 

 

 

 

 

 

R

 

C

NO

BR

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

TOP LIMIT

 

 

 

NC

 

 

 

 

 

SWITCH

 

 

INTERLOCK

 

 

 

 

 

 

SWITCH

 

 

 

 

USAS SYMBOLS

 

 

 

 

 

 

 

 

 

 

1

 

Y

 

 

 

 

 

2

 

NC

 

NC

 

 

 

 

 

 

 

3

 

TR

HELD OPEN

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

NO

 

 

 

MOTOR

 

 

 

 

NO

 

PLUG

 

 

 

HELD CLOSED

 

 

 

 

 

 

 

8

GN N COMPACTORSCHEMATIC

GN

 

 

W

 

 

W

 

 

SAFETY SWITCH

 

 

 

 

 

 

GN

 

NO

 

 

 

4

Y

C

BR 5

OR

 

 

GN

 

 

 

 

 

 

SPEED

 

V

2

BK

CW START UP

SWITCH

 

 

 

 

OR

1

R CCW START DOWN

 

OL

 

 

 

 

BR

3

GY

RUN

 

 

 

 

 

 

 

MOTOR

 

NC

NO

C

 

 

 

 

 

 

V

 

C

 

 

 

 

NC

 

 

OFF - ON

 

C

 

START - RUN

 

 

 

KEY SWITCH

 

 

NO