INSTALL DUCTWORK
CAUTION - BEFORE CUTTING HOLE IN CABINET FOR DUCT- WORK: Check for interference with floor joists, wall studs, electri- cal wiring or plumbing.
BLOWER
TRANSITION
SCREWS COLLAR
6" RD.
ELBOW & DUCT-
WORK
INSTALL ELECTRICAL WIRING
(continued)
1.Mount a standard wiring box, with
2.Run appropriate power cable into cabinet and connect it to receptacle.
3.Plug the downdraft’s power cord into the outlet.
1.Cut hole in cabinet as well as holes in wall or floor as necessary.
2.Mount the roof or wall cap and work back towards the cabinet, attaching all ductwork, elbows and transitions as previously planned. Tape all ductwork connections to make them secure and air tight.
3.Connect ductwork (and transition, if required) to downdraft. If necessary, LOOSEN nuts and screws that hold the blower in place, and slide blower left or right to meet ductwork. Re- tighten screws and nuts.
Note: A
WIRING DIAGRAM
INSTALL ELECTRICAL WIRING
WARNING: To avoid possible electrical shock, personal injury or death - Disconnect electrical power.