INSTALL COOKTOP
1.Align the cooktop with the downdraft and fasten cooktop in place.
Note: Accurate alignment of cooktop and downdraft is necessary to ensure that there is no interference when air vent is raised and lowered. There should be a gap of
USE AND CARE - (Continued)
CONTROLS
ADJUSTMENT
The downdraft is
To adjust position of activating switch:
WARNING: To avoid possible electrical shock, personal injury or death - Disconnect electrical power.
1.If downdraft is plugged into electrical outlet, unplug it.
2.Lift air vent straight up and cock it slightly so it remains in the UP position.
SWITCH
MEMBRANE
| SCREWS |
SWITCH | SWITCH |
BRACKET | COVER |
3.Remove switch cover from right end of air vent.
4.Loosen the 2 screws holding the switch bracket in place. Position switch bracket so that activating switch just comes in contact with underside of switch membrane. Tighten screws.
5.Replace switch cover, gently lower air vent into chimney, and plug in power cord.
Turn the downdraft blower ON by pressing down on the activating switch. The air vent will rise.
KNOB
The blower can be turned ON or OFF and its speed can be adjusted with the recessed knob on the right side of the air vent.
Turn the downdraft blower OFF by pressing the activating switch again. The air vent will go down and the blower will shut OFF.
Note: For most convenient operation, set the blower to your favorite speed. The blower will come on to this speed whenever the activating switch is pressed and the air vent rises.
CLEANING
WARNING: Always disconnect electric power supply before cleaning unit.
Use a mild detergent suitable for painted surfaces. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING POWDERS. Vacuum blower to clean. Do not immerse blower in water.
Wash the 2 aluminum grease filters in a mild detergent solution or a dishwasher. Remove them from the air vent by grasping the tab at the top of each filter.
Note: The filters are different sizes. Be sure to replace them as removed, (wider one on the left), with tabs UP.
SERVICING
WARNING: Always disconnect electric power supply before servicing unit.
| It may be necessary to remove the outlet assembly from the |
| cabinet in order to service components such as the blower motor |
USE AND CARE | or air vent mechanism. |
Disconnect power to the cooktop and remove it first. Reverse the | |
Always turn the downdraft blower on before you begin cooking to | steps under “MOUNT THE UNIT” to remove the downdraft from |
establish an air flow in the kitchen. Let the blower run for a few | the cabinet. |
minutes to clean the air after you turn the cooktop off. This will | Service parts are available from your local distributor. |