Broan 336 specifications Model, Read And Save These Instructions, Exterior Mounted Blower

Models: 336

1 12
Download 12 pages 56.52 Kb
Page 1
Image 1
MODEL 336

MODEL 336

EXTERIOR MOUNTED BLOWER

FOR USE WITH RANGEMASTER 60000 OR RM60000 SERIES OR 64000 SERIES RANGE HOODS

READ AND SAVE THESE INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufac- turer. If you have questions, contact the manufacturer at the address or phone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhaust- ing of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equip- ment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

WARNING

5.When cutting or drilling into wall, or ceiling, do not damage electrical wiring or other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.To reduce risk of fire, use only metal ductwork.

8.This unit must be grounded.

CAUTION

1.For general ventilating use only. Do not use to exhaust hazardous or explosive material and vapors.

2.To avoid motor bearing damage and noisy and/or unbal- anced impellers, keep drywall spray, construction dust, etc. off power unit.

3.Please read specification label on product for further informa- tion and requirements.

4.Electrical circuit, including speed control, (if used), must be rated 6 AMPS minimum.

SPECIFICATIONS

MODEL

VOLTS

AMPS

CFM

DUCT SIZE

336

120

4.3

1500

10" DIA.

 

 

 

 

 

PLAN THE INSTALLATION
ALL INSTALLATIONS

1.Locate the blower so the length of the duct run and number of elbows needed are kept to a minimum.

2.Where possible, blower should be centered between wall studs or roof rafters.

3.Avoid pipes, wires, or other ductwork that may be running through the wall.

NOTE: Horizontal discharge requires relocation of the duct opening cover plate. See hood manual for instructions.

MODEL 336

 

 

 

 

 

 

EXTERIOR BLOWER

 

 

 

 

 

 

 

10" ROUND ELBOW

 

 

 

 

10" ROUND

 

10" ROUND DUCT

 

10" ROUND DUCT

 

DUCT

 

 

 

 

 

SOFFIT

 

SOFFIT

 

 

SOFFIT

DUCT

 

ROUGH-IN

 

 

MODEL

 

WALL HOOD

WALL HOOD

 

WALL HOOD

OPENING

PLATE

 

336

CANOPY

CANOPY

 

CANOPY

COVER

 

 

EXTERIOR

(island canopy

 

(island canopy

 

(island canopy

PLATE

 

 

BLOWER

available)

 

available)

 

available)

 

 

 

 

MODEL

DUCT

 

DUCT

 

 

 

 

 

ROUGH-IN

 

MODEL 335

OPENING

18"

OPENING

18"

18"

336

PLATE

EXTERIOR

COVER PLATE

 

COVER PLATE

 

 

EXTERIOR

 

 

 

 

BLOWER

 

 

 

 

 

 

BLOWER

24" or 27"

24" or 27"

24" or 27"

ROUGH-IN

PLATE

 

 

 

TYPICAL ROOF MOUNTED INSTALLATION

TYPICAL WALL MOUNTED INSTALLATION

TYPICAL WALL MOUNTED INSTALLATION

(Vertical discharge)

(Vertical discharge - elbow to horizontal)

(Horizontal discharge)

 

INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4