MODEL 758
Page 1
DECORATIVE SERIES
CEILING VENTILATOR
READ AND SAVE THESE INSTRUCTIONSWARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OB- SERVE THE FOLLOWING:
1.Use this unit only in the manner intended by the manufacturer. If you have questions, con- tact the manufacturer at the address or tele- phone number listed in the warranty.
2.Before servicing or cleaning unit, switch power off at service panel and lock the service dis- connecting means to prevent power from be- ing switched on accidentally. When the ser- vice disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, in- cluding
4.Sufficient air is needed for proper combus- tion and exhausting of gases through the flue (chimney) of fuel burning equipment to pre- vent backdrafting. Follow the heating equip- ment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrig- eration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hid- den utilities.
6.Ducted fans must always be vented to the out- doors.
7.NEVER place a switch where it can be reached from a tub or shower.
8.This unit must be grounded.
9.This unit is U.L. listed. Type I.C. inherently protected.
CAUTION !
1.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2.This product is designed for installation in FLAT CEILINGS ONLY. Do not mount this product in a wall.
3.The light fixture assembly must be mounted to the fan housing assembly included with this product. Do not mount the light fixture as- sembly to a wiring outlet box.
4.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
5.Please read specification label on product for further information and requirements.
TYPICAL INSTALLATIONS
* |
HOUSING MOUNTED | HOUSING MOUNTED |
DIRECTLY TO JOIST | ADDITIONAL FRAMING |
2x6 (or larger) | Discharge 900 to joists. |
Discharge parallel to joists. |
|
*
* |
HOUSING MOUNTED |
|
TO 2x4 TRUSS | HOUSING MOUNTED TO 2x4 |
Requires additional framing | TRUSS |
for mounting tabs. | Requires additional framing |
Discharge parallel to joists. | for mounting tabs. |
| Discharge 900 to joists. |
*
*
HOUSING MOUNTED TO “I” JOIST | HOUSING MOUNTED TO “I” JOIST | |
Requires additional framing | ||
Requires additional framing | ||
for mounting tabs. | ||
for mounting tabs. | ||
Discharge parallel to joists. | ||
Discharge 900 to joists. |
*Additional framing must be a 2x6 (minimum height), at least
Installer: Leave this manual with the homeowner. Homeowner: Use and Care information on page 4.