Scotsman Ice CU50 service manual Harvest Time Adjustment, Harvest Time Table

Models: CU50

1 30
Download 30 pages 15.47 Kb
Page 12
Image 12

CU50

Service Manual

Harvest Time Adjustment

The harvest time can be adjusted so that all the ice harvests during the cycle, plus a few seconds extra. This is done by a button press sequence.

Note: Do not set harvest time shorter than the actual time it takes to release all the cubes.

To adjust Harvest Time:

1.Shut the machine off by holding the On/Off button in until it shuts off (Ice Making light off).

2.Press and hold the On button again for 5 seconds, then release (Ice Making light will switch off).

3.View the lights. Compare to the table below.

Harvest Time Table

 

On/Off

Water

Clean

Default

off

off

off

Add 10 seconds

on

off

off

Add 20 seconds

off

on

off

Add 30 seconds

off

off

on

Add 40 seconds

on

on

on

- 10 seconds

flash

off

off

- 20 seconds

off

flash

off

- 30 seconds

off

off

flash

- 40 seconds

flash

flash

flash

4.Select the amount of change.

5.Push and release the Clean button until the correct light pattern is displayed.

6.Push and release the On button to select that setting.

7. Push and release On/Off to return to ice making.

Ice Making

Check Water

Indicator Light

Indicator Light

On - Off

Time To

Clean - Reset

Button

Button

Clean Unit

 

 

Indicator Light

 

 

 

 

 

Control Panel

 

March 2010