VENTILATION FAN WITH LIGHT
MODEL 778WH
Page 1READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including
4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6.Ducted fans must always be vented to the outdoors.
7.This unit must be grounded.
8.This unit is U.L. listed. Type I.C. inherently protected.
TYPICAL INSTALLATIONS
POWER CABLE | MOUNTING | POWER CABLE | MOUNTING |
| HOUSING | BRACKETS | |
| BRACKETS | ||
HOUSING |
|
| For a rigid mount: |
|
|
| Brackets can be joined |
|
|
| together with |
CEILING |
| CEILING | a #8 x 3/8 |
| |||
JOIST |
| JOIST | screw |
CEILING | GLASS | CEILING | GLASS |
MATERIAL | LIGHT | MATERIAL | LIGHT SHADE |
| SHADE |
|
|
CEILING JOISTS | CEILING JOISTS |
4" ROUND |
|
DUCT | POWER |
| CABLE |
| HOUSING | MOUNTING |
| TAB | |
|
| |
SUSPENDED |
| GLASS |
CEILING MATERIAL |
| LIGHT SHADE |
SUSPENDED CEILINGS Housing hung with wires -
CAUTION
1. For general ventilating use only. Do not use to exhaust |
PLAN THE INSTALLATION
| hazardous or explosive materials and vapors. |
2. | This product is designed for installation in FLAT CEILINGS |
| ONLY. Do not mount this product in a wall. |
3. | The light fixture assembly must be mounted to the fan |
| housing assembly included with this product. Do not |
| mount the light fixture assembly to a wiring outlet box. |
4. | To avoid motor bearing damage and noisy and/or |
| unbalanced impellers, keep drywall spray, construction |
| dust, etc. off power unit. |
5. | Please read specification label on product for further |
| information and requirements. |
Leave this manual with the homeowner.
Homeowner:Use and Care information on page 4.
The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed.
Use a roof cap or wall cap that has a
Plan to supply the unit with proper line voltage and appropriate power cable.
INSULATION
(Can be placed around and over fan housing.)
FAN HOUSING
ROUND
*Purchase DUCT
separately ELBOW(S) *
ROOF
CAP *
WALL CAP *