WIRING CONNECTIONS
All wiring must comply with local codes and unit must be properly grounded.
1.While making wiring connections, support the heater assembly on the bottom of the
2.For 120 Volt operation, make wiring connections as shown in Figure 4.
3.For 240 Volt operation, make wiring connections as shown in Figure 5.
4.Use wire nuts to make connections. Insulate all connections with electrical tape.
SECURING THE HEATER
1.Dress all wiring back to into junction box.
2.Locate center holes in housing flange and align with mounting holes in grille.
3.Use two provided screws to attach grille to housing.
OPERATION
Turn thermostat fully clockwise to HIGH position. Allow heater to run until room is at desired temperature. Adjust thermostat as required to maintain desired temperature. Turn the thermostat to FULL COUNTERCLOCKWISE position when operation is no longer desired.
120vAC
GREEN | GREEN OR BARE |
| |
GROUND | GROUND |
| |
4 | YELLOW |
|
|
3 | WHITE | white |
|
2 | RED |
| 120vAC 60HZ |
|
| ||
1 | BLACK | BLACK |
FIGURE 4
240vAC
GREEN | GREEN OR BARE |
| |
GROUND | GROUND |
| |
4 | YELLOW | RED OR white |
|
3 | WHITE | NO |
|
|
| CONNECTION |
|
2 | RED | NO | 240vAC 60HZ |
| CONNECTION | ||
1 | BLACK | BLACK |
FIGURE 5
Thermal protector: If for any reason temperatures increase beyond normal limits, a safety thermal fuse will shut heater off. The heater will require servicing by a qualified electrician.
Check entire installation to determine cause of overheating.
SERVICE PARTS
Key No. | Part No. | Description |
1 | 99111432 | Grille |
2 | 99360253 | Knob |
3 | 52872039 | Grille Screw |
4 | 44953000 | Heater Assembly (9810WH) |
| 44954000 | Heater Assembly (9815WH) |
5 | 57271000 | Thermostat, with Mounting Nut |
6 | 33384000 | Thermostat Cover |
7 | 33178000 | Blower & Motor |
8 | 0936B000 | Thermal Protector |
9 | 61962000 | Heat Box |
10 | 35841000 | Thermal Fuse (2 required) |
|
|
| 9 |
5 |
| 7 | 10 |
|
|
| |
1 |
|
|
|
3 |
|
| 8 |
| 6 |
| 4 |
|
|
|
2
WARRANTY
During this
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP START- ERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negli- gence, accident, improper maintenance or repair (other than by
The duration of any implied warranty is limited to the
BLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequen- tial damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify
99044155B