GENERAL REQUIREMENTS AND SPECIFICATIONS (CONT’D)
|
|
| 240 VOLTS – SINGLE PHASE |
|
| TEMP. RISE @ 0.20 IN. W.C. | |||||
|
|
|
|
|
|
|
|
|
|
|
|
MODEL NO. | KW |
| BTUH | AMPS INCL. MOTOR |
| HP | BLOWER | °C | °F | *SPEED | RPM |
|
|
|
|
|
|
|
|
|
|
|
|
21D10 | 10 |
| 34120 | 46 |
| 1/3 |
| 21 | 70 | 814 | |
|
|
|
|
|
|
|
|
|
|
|
|
21D15 | 15 |
| 51180 | 67 |
| 1/3 |
| 24 | 25 | 814 | |
|
|
|
|
|
|
|
|
|
|
|
|
21D18 | 18 |
| 61420 | 77 |
| 1/3 | 10” x 8” | 27 | 81 | 814 | |
21D20 | 20 |
| 68240 | 86 |
| 1/3 | (254 mm x 203 mm) | 33 | 91 | 814 | |
|
|
|
|
|
|
|
|
|
|
|
|
21D23 | 22.5 |
| 76842 | 94 |
| 1/3 |
| 36 | 97 | 814 | |
|
|
|
|
|
|
|
|
|
|
|
|
21D25 | 25 |
| 85003 | 107 |
| 1/3 |
| 37 | 99 | 814 | |
|
|
|
|
|
|
|
|
|
|
|
|
21D27 | 27 |
| 92130 | 116 |
| 3/4 | 12” x 8” | 36 | 97 | 707 | |
|
| (304 mm x 203 mm) | |||||||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
*FACTORY SETTINGS. |
|
|
|
|
|
|
|
|
| ||
SUBJECT TO CHANGE WITHOUT NOTICE. |
|
|
|
|
|
|
10” x 8” (254 mm x 203 mm) BLOWER
| FLOW |
| STATIC PRESSURE |
| |||
SPEED | (INCHES OF WATER COLUMN) | ||||||
RATE | |||||||
|
|
|
|
|
| ||
|
| 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | |
|
|
|
|
|
|
| |
LOW** | CFM | 756 | 749 | 740 | 729 | 713 | |
L/s | 357 | 353 | 349 | 344 | 337 | ||
| |||||||
|
|
|
|
|
|
| |
CFM | 1035 | 1018 | 997 | 971 | 935 | ||
L/s | 488 | 480 | 470 | 458 | 441 | ||
| |||||||
|
|
|
|
|
|
| |
CFM | 1177 | 1157 | 1132 | 1102 | 1063 | ||
L/s | 556 | 546 | 534 | 520 | 502 | ||
| |||||||
|
|
|
|
|
|
| |
HIGH | CFM | 1301 | 1276 | 1247 | 1207 | 1145 | |
L/s | 614 | 602 | 588 | 569 | 540 | ||
| |||||||
|
|
|
|
|
|
|
WARNING:
12” x 8” (304 x 203 mm) BLOWER
| FLOW |
| STATIC PRESSURE |
| |||
SPEED | (INCHES OF WATER COLUMN) | ||||||
RATE | |||||||
|
|
|
|
|
| ||
|
| 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | |
|
|
|
|
|
|
| |
LOW** | CFM | 727 | 699 | 667 | 636 | 606 | |
L/s | 343 | 330 | 315 | 300 | 286 | ||
| |||||||
|
|
|
|
|
|
| |
CFM | 912 | 897 | 878 | 853 | 823 | ||
L/s | 431 | 423 | 414 | 402 | 388 | ||
| |||||||
|
|
|
|
|
|
| |
CFM | 1216 | 1200 | 1181 | 1157 | 1129 | ||
L/s | 574 | 566 | 557 | 546 | 533 | ||
| |||||||
|
|
|
|
|
|
| |
HIGH | CFM | 1640 | 1601 | 1558 | 1513 | 1466 | |
L/s | 774 | 755 | 735 | 714 | 692 | ||
| |||||||
|
|
|
|
|
|
|
**These speeds can only be run with heater off, for cooling/ventilation purposes only.
OPERATING OPTIONS
The furnace is shipped from the factory in a “Standard Heating Mode” (all switches in the Down position). When the thermostat calls for heat, the automatic controls will be activated and the furnace turns “ON”.
The blower will run at low speed or higher speed (as selected by
SPEED SELECTOR switch).
HIGH
LOW
SPEED SELECTOR
As the furnace heats up, it automatically switches to a medium speed when additional elements are activated by the electronic control, if it was initially set to run at low speed. The timing of this blower speed change will depend on whether COLD or MILD is selected on the SEASON SELECT switch.
You may, however, change from the Standard Heating Mode by using the controls built into your furnace.
MILD
COLD
SEASON SELECT
The SPEED SELECTOR switch is used to control the fan speed | During spring or fall, you may require less rapid response when | |||
(ventilation). Even if there is no call for heat, the ventilation can be | the thermostat calls for heat. |
| ||
controlled by the thermostat; the fan speed is determined by this | When MILD is selected, it takes more time to bring all the elements online. | |||
switch. | When COLD is selected, the heating elements come online faster. | |||
LOW – The blower motor will operate at low speed. |
| |||
|
|
|
| |
| MILD SEASON (First Stage) |
| COLD SEASON (Second Stage) | |
HIGH – The blower motor will operate at a higher speed. |
|
| ||
| Slow Response Sequence |
| Rapid Response Sequence | |
|
|
|
|
|
|
| Element 1 - Heat on instantly |
| Element 1 - Heat on instantly |
|
|
|
|
|
|
| Blower on after 3 seconds delay |
| Blower on after a 3 seconds delay |
|
|
| ||
| Elements 3 and 5 after 1 minute delay | Elements 3 and 5 after 10 seconds delay | ||
|
|
|
|
|
|
| Element 2 after 2 minutes delay |
| Element 2 after 20 seconds delay |
|
|
| ||
| Elements 4 and 6 after | Elements 4 and 6 after 30 seconds delay | ||
|
|
| ||
| NOTE: Elements 4, 5 and 6 only where applicable. |
3