TROUBLESHOOTING

The first step in identifying an operational problem is to determine whether the fault is in the furnace or in the thermostat and/or its connecting wiring.

To help make this determination, the furnace is equipped with a “Thermostat ON” diagnostic light. If the light is “ON”, it indicates the thermostat has closed and is calling for heat; the blower should be running. If the light is “OFF”, the furnace should not be operating.

1.If the furnace will not start:

Turn the thermostat to its highest setting. If the light goes on, the thermostat has closed, so the fault is in the furnace. If the light does not go on, the thermostat or its connecting wiring is the problem.

2.If the furnace will not turn off:

Turn the thermostat to its lowest setting. If the light goes off and the furnace continues to run, the thermostat has opened properly and the fault is in the furnace. If the light stays on, the fault is in the thermostat or its connecting wiring.

After the fault area is isolated by use of the diagnostic light, a check of the following components can be made more efficiently.

PROBLEM

POSSIBLE DEFECTIVE PARTS OR COMPONENTS

 

 

1. The furnace will not turn on

• Thermostat

 

• Circuit breaker or fuse is open

 

• Motor or capacitor

 

SPEED SELECTOR switch (open contact)

 

• Electronic control

 

• Transformer

 

 

2. Motor runs continuously

• Thermostat wires incorrectly attached to furnace

 

 

3. Elements on, but motor does not run

• Motor or capacitor

SPEED SELECTOR switch (open contact)

 

 

• Electronic control

4. Motor going on and off in short cycles

• Heat anticipator in thermostat incorrectly set

(or in too long cycles)

or may be defective

 

 

5. Must set thermostat much higher (or lower)

• Thermostat is not leveled or out of calibration

than the desired house temperature

 

 

 

6. Not enough heat

• One or more defective elements or relays

 

SEASON SELECT switch in MILD position

 

• Safety limits opening because duct obstruction

 

or dirty filters are restricting air flow

 

• Defective or incorrectly wired two-stage

 

or outdoor thermostat

 

• Lack of enough cold air returns in house

 

 

7. Two-stage or outdoor thermostat not operating properly

SEASON SELECT switch not in MILD position

 

 

SIXTY-MONTH LIMITED WARRANTY FOR NORTRON PRODUCTS

Broan-NuTone Canada (Broan-NuTone) warrants to the original consumer purchaser of Notron products that such products will be free from defects in materials or workmanship for a period of sixty (60) months from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

During this sixty-month period, Broan-NuTone will, at its option, repair or replace without charge, any product or part which is found to be defective under normal use and service. This product or part should be shipped prepaid by the customer to the company factory or the nearest authorized service center. THIS WARRANTY DOES NOT EXTEND TO FILTERS, FURNACE KITS SOLD SEPARATELY, DUCTS, AND ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. Broan-NuTone does not accept any responsibility for transportation of repaired part or replaced product mentioned above and for reinstallation costs.

The duration of any implied warranty is limited to the sixty-month period as specified for the express warranty. Some jurisdictions do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.

BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights, which vary from province to another. This warranty supersedes all prior warranties, and applies only in Canada territorial limits.

To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.

Broan-NuTone Canada; 1140 Tristar Drive, Mississauga, ON L5T 1H9 www.broan.ca 877-896-1119

10

Page 10
Image 10
Broan 30042432A, D SERIES ELECTRIC FURNACE warranty Troubleshooting, Problem Possible Defective Parts or Components

30042432A, D SERIES ELECTRIC FURNACE specifications

The Broan 30042432A, D Series Electric Furnace stands out as a reliable and efficient heating solution for residential and commercial applications. Designed with advanced technology and robust features, this electric furnace provides superior performance, durability, and energy efficiency, ensuring comfortable indoor environments even in the coldest months.

One of the defining features of the Broan D Series Electric Furnace is its compact design, making it suitable for various locations without compromising on efficiency. The unit is engineered to maximize heating output while minimizing energy consumption. This is achieved through its powerful heating elements that provide quick and consistent warmth, ensuring that spaces reach desired temperatures rapidly.

The furnace is equipped with a multi-speed blower motor that enhances airflow throughout the premises. This feature ensures that heat is distributed evenly, preventing cold spots and enhancing overall comfort. The motor operates quietly, allowing users to enjoy a peaceful environment without the disturbances associated with traditional heating systems.

In terms of safety, the Broan 30042432A incorporates several innovative technologies. It includes over-temperature protection, which automatically shuts off the furnace if the internal temperature exceeds safe limits. This not only safeguards the appliance but also provides peace of mind to users. Additionally, the furnace's construction utilizes high-quality materials that are resistant to high temperatures, further enhancing its safety profile.

The D Series also boasts smart technology features, including compatibility with programmable thermostats, allowing users to customize heating schedules and optimize energy usage according to their lifestyles. This feature is particularly beneficial for those looking to minimize utility costs while still maintaining a comfortable living environment.

Maintenance of the Broan Electric Furnace is simplified through its accessible design, allowing for easyfilter replacement and general upkeep. This ease of maintenance ensures that the unit operates efficiently over its lifespan, providing a consistent heating solution.

In summary, the Broan 30042432A, D Series Electric Furnace epitomizes a perfect blend of efficiency, safety, and user-friendly design. Its advanced technologies and thoughtful features make it an ideal choice for those seeking reliable heating solutions, ensuring comfort without compromising on performance or safety. With the increasing demand for sustainable living solutions, this furnace stands as a cornerstone for modern HVAC systems, promising warmth and comfort in every setting.