USING OPTIONAL EQUIPMENT
1. | |
| (The SEASON SELECT switch must be in the MILD position). |
| Follow the directions supplied with the |
| thermostat in conjunction with the furnace wiring diagram. |
2. | AIR CONDITIONING |
| Your furnace is equipped with all the controls required for the |
4.INTERLOCK CONNECTION
When the electric furnace is used in combination with another device (as for example, a wood burning furnace), it is recommended to perform the connection by referring to the wiring diagram below. The burning furnace thermostat will then turn automatically on the blower in the electric furnace.
addition of air conditioning (except the |
The evaporator coil may be installed by a local contractor in |
sheet metal plenum of his own manufacture. The coil should be |
located: Centered over the “chimney” of the furnace 4” (102 mm) |
to 6” (152 mm) above the top of the furnace. |
Make sure no air is allowed to bypass the cooling coil during |
cooling operation. If the discharge opening is a great deal larger |
than the coil, and the ductwork is correspondingly larger than |
the coil, you may want to use a bypass damper for heating. The |
damper would be closed in summer, directing all air flow |
External Request for Fan Activation
Relay |
NC |
COM |
NO |
Furnace
Thermostat
G R
Electric Furnace System
Furnace
R24 VAC Power Output
GCall for FAN
through the coil. In winter the damper would be open to allow |
air to bypass the coil. |
Typical
THERMOSTAT
FURNACE
CONDENSER
WIRING COLOR CODES
C | G | R | W1 | W2 | Y |
|
|
|
|
|
|
|
|
|
| WHITE |
|
COMMON | GREEN | RED | WHITE | (BLUE | YELLOW |
|
|
|
| OPTIONAL) |
|
|
|
|
|
|
|
3.ELECTRONIC AIR CLEANERS AND/OR POWERED FURNACE HUMIDIFIERS
These units operate at 120 V. Your 240 V furnace is designed so that Model FK120 adaptor kit can be mounted inside the furnace to supply the required 120 V. Instructions for mounting and wiring are included with the kit.
MAINTENANCE
MOTOR: The motor is lubricated for life and needs no oiling.
FILTERS: Size is 20” x 20” x 1” (508 mm x 508 mm x 25 mm). Should be inspected and replaced when dirty. Ordinarily replacement is required twice per heating season and, perhaps, a third time if continuous blower operation is used.
NOTE: Each element has an automatic reset thermal
!WARNING
Cut 240 V supply before removing the front panel!
The reason for the failure should be investigated before
5