PREPARE THE HOOD, cont’d.

NON-DUCTED HOODS ONLY

3.Install the non-ducted recirculation plenum through the upper rectangular openings in the support frame. Fig. 13

4.Install the 5” diameter duct connector to plenum. Twist and lock to secure. Fig. 14.

5.Attach 5” diameter metal expandable duct to the plenum. When stretched, it must be long enough to reach the bottom of the support frame. Fig. 14.

6.Duct tape all joints to make them secure and air tight.

NON-DUCTED

RECIRCULATION

PLENUM

FIG.13

INSTALL UPPER

DECORATIVE FLUE

DUCTED HOODS ONLY (8-FOOT AND 9-FOOT CEILINGS)

1.Install and secure the upper flue to the support frame with (2) 2.9x9.5mm mounting screws. Fig. 15.

On 8-foot ceilings, install with air vents down.

On 9-foot ceilings, install upper flue with air vents up.

(10-FOOT CEILINGS)

2.Discard the upper flue supplied with the hood. Replace with the upper flue supplied with flue extension model FX54SS.

3.Install and secure the upper flue to the support frame with (2) 2.9x9.5mm mounting screws.

DUCT

CONNECTOR

5” METAL EXPANSION DUCT

FIG.14

MOUNTING SCREWS

(2.9x9.5mm)

VENTS “UP”

VENTS

UPPER“DOWN” FLUE

FIG.15