8. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) HOOD ONLY)

8. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) HOOD ONLY)

All internal blower hoods are factory shipped with the blowers mounted for a vertical discharge configuration. For a horizontal discharge configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the inner back panel of the hood. The procedure below applies for one or two blowers.

LEFT SIDE MOUNTING

SCREW LOCATION

Using a 5/16” socket, remove all blower mounting screws from the inner top of the hood. Keep the screws for further use.

RIGHT SIDE

MOUNTING SCREW

LOCATION

HD0282

HD0269

Slide the blower to disengage its flange from the retaining bracket.

HD0270

Rotate the blower and engage its flange in the back wall retaining bracket.

Using a 5/16” socket and the screws previously removed, secure the blower to the hood.

RIGHT SIDE

MOUNTING SCREW

LOCATION

LEFT SIDE MOUNTING

SCREW LOCATION

HD0288

HD0289

 

- 9 -

Page 9
Image 9