2.CONTROLS (CONT’D)
2.3OPERATING 40425 CONTROLLER
The included wall control 40425 is intented for GSHH3K and GSEH3K units only. The wall control is in OFF mode when power is applied for the first time. The mode does not change following a power failure.
2.3.140425 CONTROLLER DESCRIPTION
ILLUMINATES IN |
| |
ALL MODES |
| |
EXCEPT OFF | 40425 | |
MODE. | ||
|
• PRESS EITHER
BUTTON TO CHANGE
CONFIGURATION SETTING
(SEE SECTION 2.3.3).
•PRESS BOTH
BUTTONS TO RESET
THE FILTER COUNTER OR
PREFILTER COUNTER.
VC0098
PRESS THIS BUTTON TO
SWITCH MODE
(SEE SECTION 2.3.2).
2.3.2USING 40425 CONTROLLER
FILTER AND PREFILTER
MAINTENANCE LED.
FLASHES WHEN IT IS
TIME TO REPLACE
PREFILTER AND WASH
CORE FILTERS.
SEE
MAINTENANCE IN
SECTION 3.1.
LIGHTS UP WHEN IT IS
TIME TO REPLACE FILTER
AND PREFILTER AND
WASH CORE FILTERS.
SEE ANNUAL
MAINTENANCE
SECTION 3.2.
PRESS THIS BUTTON TO ACCESS CONFIGURATION PARAMETERS
(SEE SECTION 2.3.3).
The wall controller 40425 provides 5 operation modes. Press the Mode button to select the desired mode.
NORMAL MODE (MIN) | BOOST MODE (MAX) | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The unit exchanges air
at normal speed.
The outdoor
temperature* is displayed.
The unit exchanges air
at high speed.
The outdoor
temperature* is displayed.
*The outdoor temperature reading is taken from the unit FRESH AIR FROM OUTSIDE port; due to the lenght of the insulated duct, the reading is slightly different from the real outside temperature.