2.3.3 40425 WALL CONTROLLER CONFIGURATION
See the configuration table below for the list of configuration parameters.
Press the Menu button for 3 seconds to enter or exit the configuration menu.
NOTE: The wall control automatically saves any changes and exits the
configuration menu if no button is pressed within the next 60 seconds.
Press the Menu button briefly to advance to the next parameter (menu number).
Press the or button to change the parameter setting.
CONFIGURATIONTABLE
2. CONTROLS (CONT’D)
MENU
NUMBER PARAMETER OPTIONS DEFAULT
SETTING DESCRIPTION
1TEMPERATURE
FORMAT °C / °F °C SELECTS BETWEEN °C AND °F DISPLAY.
2AUTO MODE
OPERATION RE / OF RE
SELECTS BETWEEN AIR RECIRCULATION
(RE) AND OFF (OF).
SEE SECTION 2.3.2.
3
AUTO MODE
LOW
TEMPERATURE
LIMIT
-30°C TO 0°C
(-22°F TO 32°F)
(-25°C)
(-13°F)
PREVENTS AIR EXCHANGE IN AUTO
MODE IF THE OUTDOOR TEMPERATURE
IS TOO LOW.
SEE SECTION 2.3.2.
4
AUTO MODE
HIGH
TEMPERATURE
LIMIT
0°C TO 30°C
(32°F TO 86°F)
(27°C)
(81°F)
PREVENTS AIR EXCHANGE IN AUTO
MODE IF THE OUTDOOR TEMPERATURE
IS TOO HIGH.
SEE SECTION 2.3.2.
5BACKLIGHT
MODE AU / ON AU
AU: THE SCREEN ILLUMINATES FOR 12
SECONDSWHEN ANY KEY IS PRESSED
ON: THE SCREEN IS PERMANENTLY
ILLUMINATED.
- 8 -