MODELS L100L • L150L • L200L • L250L • L300L
TYPICAL INSTALLATION
MOUNTING (New Frame Construction)
ROUND DUCT* | Mounting brackets |
| |
| position for ½” |
| ceiling material. |
ADDITIONAL |
|
1½” FRAMING | CEILING JOIST |
| (16” centers shown) |
| MOUNTING |
| SCREW |
Blower |
|
in straight through |
|
discharge position. |
|
MOUNTING (Existing Frame Construction) | |
2 X 4 FRAMING |
|
(wide side down) |
|
ROUND DUCT* |
|
CEILING JOIST |
|
(16” centers |
|
shown) |
|
MOUNTING |
|
BRACKETS |
|
(Attached to | FINISHED |
opposite sides | CEILING |
of housing & | MATERIAL |
|
*L100L & L150L use 6” round duct.
L200L, L250L, & L300L use 8” round duct.
Page 2
TYPICAL INSTALLATION
WIRING
BLACK
TO
BLACKTOP / BACK
OF HOUSING
GROUND TO
WIRING PLATE
WIRING
PLATE
WHITE
TO
WHITE
120 VAC LINE IN
Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.
DUCTING (Horizontal blower discharge)
ROOF CAP |
| |
ROUND DUCT* |
| |
ROUND | WALL | |
CAP | ||
ELBOW* | ||
|
Two ways to connect ductwork to a
*L100L & L150L use 6” round duct.
L200L, L250L, & L300L use 8” round duct.
IMPORTANT:
Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork. Use duct tape to make ductwork connections secure and
Remove shipping ring from blower inlet
Remove the shipping ring from the blower inlet before operating the ventilator.