TOP RECTANGULAR

ALLURE™ QS1 SERIES RANGE HOOD

Page 4

PREPARE THE HOOD

TOP RECTANGULAR

 

DUCT KNOCKOUTSEMI-CIRCULAR

(Remove for 3¼” x 10”

DUCT KNOCKOUT

Vertical & for 7” Round

(Remove for 7” Round

Discharge)

Discharge)

 

REAR

RECTANGULAR

DUCT KNOCKOUT

(Remove for 3¼” x 10” Horizontal Discharge)

11Remove appropriate Duct Knockout(s) from top or back of DUCT KNOCKOUT hood.

CONNECT WIRING

SEMI-CIRCULAR WARNING: To reduce the risk of electric shock, make sure power is switched off at the service (Remove for 3¼” x 10” Horizontal Discharge)CONNECT WIRING panel. Lock or tag service panel to prevent power

from being switched on accidentally.

from being switched on accidentally. HOUSE WIRING (120 VAC)

CARDBOARD (Use to protect cooktop)

UP TO 1”

TAPE

 

SIDE-TO-SIDE

 

ADJUSTMENT

 

1

TOP/BACK

EDGE

Connect House Wiring (120 VAC) to hood. Use a piece of Cardboard to protect the cooktop, if necessary.

 

 

PIVOT

DAMPER/DUCT

 

 

CONNECTOR

 

(Vertical discharge

 

position shown)

12 3¼” x 10” Ducted Discharge Only: Attach Damper/Duct Connector over knockout opening. Make sure damper Pivot is nearest to Top/Back Edge of hood. Remove Tape from damper flap.

137” Round Ducted Discharge Only: Re-install 7” Round Duct Manual background Plate removed in Step #1 under “PREPARE THE HOOD” section. Install a 7” round damper (purchase separately). Damper flap must open freely in direction of air flow (away

from range hood).

GREEN

GROUND

Manual background SCREW

2 Connect house black to hood black wire, house white to hood

 

white wire, and house ground under Green Ground Screw.

 

Securely tighten cable clamp onto house wiring.

3

Replace wiring cover.

NOTE

To accomodate off-center ductwork, the Damper/Duct

 

Connector can be installed up to 1-inch on either side of

 

hood center or the 7” Round Duct Plate can be installed up to ½” on either side of hood center. In extreme off-center installations, one end of the duct connector may need to be trimmed to clear the electrical cable clamp.

Page 4