ALLURE® QS3 SERIES RANGE HOOD
Page 5
CONNECT WIRING
WARNING: To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent power
from being switched on accidentally.
HOUSE
WIRING
(120 VAC)
CARDBOARD (Use to protect cooktop)
1 Connect House Wiring (120 VAC) to hood. Use a piece of Cardboard to protect the cooktop, if necessary.
GREEN
GROUND
SCREW
2 Connect house black to hood black wire, house white to hood white wire, and house ground under Green Ground
Screw. Securely tighten cable clamp onto house wiring.
INSTALL HOOD
KEYHOLE (4) | MOUNTING SCREW (4) |
1Hang hood from (4) Mounting Screws. Slide hood towards wall until mounting screws are engaged in narrow end of (4)
Keyholes. Tighten mounting screws securely. A long screwdriver works best.
2 Replace bottom cover.
DUCT
TAPE
3 Connect ductwork to hood. Use Duct Tape to make joints secure and air tight.
PAR20,
50W MAX.
HALOGEN
BULB (2)
- or - R16, 40W MAX.
INCANDESCENT
BULB (2)
4 Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16, 40 W Maximum Incandescent Bulbs. Purchase bulbs
separately.
!CAUTION: Bulbs may be hot! Refer to bulb packaging for further information.
5 |
Replace filters, turn on power at service panel, and test for proper operation.