CONNECT WIRING

ALLURE® QS3 SERIES RANGE HOOD

Page 5

CONNECT WIRING

from being switched on accidentally. WARNING: To reduce the risk of electric shock, make sure power is switched off at the service (120 VAC)INSTALL HOOD panel. Lock or tag service panel to prevent power

from being switched on accidentally.

Manual background HOUSE

WIRING

(120 VAC)

CARDBOARD (Use to protect cooktop)

1 Connect House Wiring (120 VAC) to hood. Use a piece of Manual background Cardboard to protect the cooktop, if necessary.

GREEN

GROUND

Manual background SCREW

2 Connect house black to hood black wire, house white to Manual background hood white wire, and house ground under Green Ground

Screw. Securely tighten cable clamp onto house wiring.

INSTALL HOOD

KEYHOLE (4)

MOUNTING SCREW (4)

1Hang hood from (4) Mounting Screws. Slide hood towards Manual background wall until mounting screws are engaged in narrow end of (4)

Keyholes. Tighten mounting screws securely. A long screwdriver works best.

2Manual background Replace bottom cover.

DUCT

TAPE

3 Connect ductwork to hood. Use Duct Tape to make joints Manual background secure and air tight.

PAR20,

50W MAX.

HALOGEN

BULB (2)

- or - R16, 40W MAX.

INCANDESCENT

BULB (2)

4 Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16, Manual background 40 W Maximum Incandescent Bulbs. Purchase bulbs

separately.

!CAUTION: Bulbs may be hot! Refer to bulb packaging Manual background for further information.

5

Replace filters, turn on power at service panel, and test for proper operation.