Broan QTRE080R warranty Install Housing, Connect Electrical Wiring

Models: QTRE080R

1 8
Download 8 pages 45.67 Kb
Page 5
Image 5

MODEL QTRE080R

Page 5

MOUNTING

FRAME

DUCT CONNECTOR SCREW

BRACKET (provided)

EXISTING

ELECTRICAL

WIRING

WIRING PLATE (shown

removed

from fan housing)

INSTALL HOUSING

HOUSING

5.Attach the duct connector bracket to the mounting frame using the (1) screw provided. Position the bottom edge of the duct connector bracket so it touches the finished surface of the ceiling and tighten the screw.

CONNECT ELECTRICAL WIRING

SCREW (5)

(provided)

7.Position the two movable brackets of the mounting frame directly across from each other and insert the housing into the mounting frame until it touches the duct connector bracket. Secure the housing to the mounting frame and duct connector bracket using the (5) screws provided.

6.Retrieve the existing electrical wiring from above the ceiling and use a UL approved connector to secure it to the wiring plate. Re-attach wiring plate to fan housing, if necessary. Connect wires as shown in wiring diagrams.

INSTALL THUMBSCREW & GRILLE

THUMBSCREW

8.Install thumbscrew through flange of motor plate as shown.

9.Squeeze grille springs and insert them into slots on each side of housing. Push grille against ceiling.

Page 5
Image 5
Broan QTRE080R warranty Install Housing, Connect Electrical Wiring