CONNECT DUCTWORK

FLUE MOUNTING

 

BRACKET

Ducted Configuration

MOUNTING SCREWS

 

1.Adjust the width of the flue mounting bracket to equal the inside width of decorative flue. Insert and tighten mounting screws to hold bracket width.

2.Use mounting screws and wall anchors to secure flue mounting bracket to the ceiling as shown.

3.Use 6" round metal duct to connect the

duct collar on the hood to the ductwork

 

 

above.

 

 

MOUNTING SCREWS

4. Use duct tape to make all joints secure

 

 

and air tight.

 

 

 

5. Insert the decorative flues setting them on

 

 

the hood.

 

 

 

6. Extend the upper flue to the ceiling and

 

=

secure with two mounting screws.

 

 

 

 

 

 

 

=

 

 

 

 

DECORATIVE

 

 

 

 

FLUE

 

 

 

 

DUCT TAPE

 

 

 

 

 

 

 

 

FASTEN

 

 

 

 

 

 

FLUE TO

 

 

 

UPPER

 

 

 

BRACKET

 

 

 

WITH

 

 

 

MOUNTING

 

6" ROUND

 

SCREWS

 

METAL DUCT

 

 

 

 

 

 

 

 

 

- 7 -

Page 7
Image 7
Broan RM52000, RM51000 manual Connect Ductwork, Ducted Configuration