8. INSTALL THE ROUGH-IN PLATE TO THE HOOD (CONT’D)

Wiring!WARNING

0

Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.

Remove wiring cover from rough-in plate and set aside.

Remove appropriate knockout from rough-in plate. As you are installing the rough-in plate, feed 6” of power cable through knockout opening and attach cable to wiring box with appropriate connector.

Connect wires as shown in blower instructions. Reinstall wiring cover.

9. INSTALL THE OPTIONAL SOFFIT CHIMNEY

(OPTIONAL) RMN Series

Refer to the instructions included with the soffit chimney.

10. INSTALL BLOWER

Refer to instructions included with blower.

Once the blower is installed, plug the blower unit into the female receptacle and the power supply onto the male connector inside the hood. DO NOT plug the two cords into each other.

HE0003

11. INSTALL LIGHT BULBS AND WARMING LAMPS

Install (2) heat lamp bulbs. Use BR40 size, 250W Max., infrared bulbs only (purchase separately).

Install (3) halogen light bulbs. Use PAR20 50W Size (purchase separately).