Broan RMIP33 Remove the KNOCK-OUT Opening Interior Blower, Install the Deviator Interior Blower

Models: RMIP33

1 48
Download 48 pages 62.6 Kb
Page 8
Image 8

10. REMOVE THE KNOCK-OUT OPENING (INTERIOR BLOWER)

Remove the knockout on rough-in plate. See picture below.

CAUTION

When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove the knockout corresponding to the ducting installed (10’’ or 14’’ adapter/damper).

14’’

KNOCKOUT

10’’

KNOCKOUT

HD0077

Removing vertical knockout opening on rough-in plate

11. INSTALL THE DEVIATOR (INTERIOR BLOWER)

Install the deviator as shown.

NOTE : To prevent the deviator from sliding out of the rough-in plate, put some tape on the deviator base after sliding it into the rough-in plate (provided with the P5 and P8 blower) opening. If installed correctly, the deviator will protrude about 1/8” above the rough-in plate.

HD0087

12. INSTALL THE ADAPTER (INTERIOR BLOWER)

Using two (2) no. 6 x 1/2’’ screws provided with insert, secure the adapter to the top of the rough-in plate. Remove tape from damper flap. Seal the adapter to the rough-in plate by using duct tape.

NOTE : Make sure that the damper pivot is located towards the front of the hood.

HD0005

HD0006

- 8 -

Page 8
Image 8
Broan RMIP33 Remove the KNOCK-OUT Opening Interior Blower, Install the Deviator Interior Blower, 14’’