18. INSTALL THE BLOWER (INTERIOR BLOWER) (CONT’D)
Install (4) no. 8 x 3/8’’ screws into the location as shown in the pictures below (single blower or dual blower). Do not tight- en screws down fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the key- hole). Slide the blower to its position (screws in the small part of the keyhole). Tighten the (4) screws.
HD0044
Single blower (P5)
HD0045
Dual blower (P8)
Secure the blower by installing 2 more no. 8 x 3/8’’ screws for the P5 blower and 4 more no. 8 x 3/8’’ screws for P8 into the locations shown in the pictures below (single blower or dual blower). Reinstall impeller(s) and cover.
HD0080
HD0081
Single blower (P5)
FOR DUAL BLOWER UNIT, MAKE SURE THE IMPELLERS ARE CORRECTLY INSTALLED, THE INSERT WILL NOT WORK PROPERLY IF REVERSED. Both impellers are different in the dual blower, one rotates clockwise and the other counterclockwise. Each wheel and motor have an arrow and a number on them, you have to match them correctly (see drawing beside).
Dual blower (P8)
FRONT
1 | 2 |
HD0023
! WARNING
Never plug the
Plug the power supply to the
A
B
HE0022
- 11 -