9. INSTALL THE TRANSITION
Attach the provided transition to top of hood. Use metal duct tape to make all joints secure and air tight.
HD0057
10. INSTALL THE DECORATIVE FLUE (OPTIONAL)
OPTIONAL DECORATIVE FLUE AEWPD SERIES
Refer to the instructions included with the optional decorative flue.
CAUTION
If this decorative flue is installed in a salt water area (example: coast), rinse all surfaces once a week with clear water (even if the hood is not used), and wipe dry completely.
11. INSTALL THE HOOD
Rest the top back cavity of the hood on the wood mounting strip.
CAUTION
Hold the hood until it is completely secured to the wood mounting strip.
Attach transition to 10” round duct. Secure the hood to wood mounting strip with
(5)screws provided at locations shown. Drill (2) 3/16’’ size holes into the drywall for wall anchors through the existing holes in the inside hood back in the locations shown. Then, install the two wall anchors with the remaining #8 x 3/4” screws and the (2) washers provided.
TOP OF HOOD (INSIDE VIEW) |
MOUNTING SCREWS LOCATION |
BACK OF HOOD (INSIDE VIEW) |
WALL ANCHORS LOCATION |
HD0184 |
12.INSTALL THE BLOWER (INTERIOR BLOWER ONLY)
SLOT IN TOP
Assemble barrel nut (packed with blower) approximately halfway onto threaded stud on top inside of hood.
BARREL NUT ON THREADED STUD
OF HOOD
Lift blower to top inside of hood. Slide blower back to engage blower tab with slot in hood top and slot in blower with barrel nut.
DISCHARGE |
| DISCHARGE |
OPENING |
| OPENING |
|
HD0061
Use a long,
BLOWER MOTOR
BARREL NUT
SCREWDRIVER
HD0054