Brocade Communications Systems RX Series manual Brocade bigiron rx series system specifications

Models: RX Series

1 8
Download 8 pages 29.71 Kb
Page 7
Image 7

IPv6 Routing

• RFC 2080 RIPng for IPv6

 

• RFC 2740 OSPFv3 for IPv6

 

• IETF Draft_ietf_isis_IPv6 IS-IS for IPv6

 

• RFC 2545 Use of MP-BGP-4 for IPv6

IPv6 Multicast

• RFC 2362 PIM-SM

 

• RFC 2710 Multicast Listener Discovery (MLD) for IPv6

 

• RFC 3306 Unicast-Prefix-based IPv6 Multicast

 

Addresses

 

• RFC 3810 MLDv2

 

• RFC 4602 PIM-SM (Partial Address)

 

draft-holbrook-idmr-igmpv3-ssm—IGMPv3 & MDLV2

 

for SSM

 

draft-ietf-ssm-arch SSM for IP

IPv6 Transitioning

• RFC 2893 Transition Mechanisms for IPv6 Hosts

 

and Routers

RFC 3056 Connection of IPv6 Domains via IPv4 Clouds

Network Management

IronView Network Manager (INM) Web-based graphical user interface

Integrated Standard-based Command Line Interface (CLI)

RFC 3176 sFlow

RFC 854 Telnet

RFC 2068 HTTP

RFC 2578 and 3410 SNMPv2 and v3

RFC 1757 RMON Group partial 1, full 2, 3, and 9

HP OpenView for Sun Solaris, HP-UX, IBM’s AIX, Linux and Windows NT

SNMP MIB II

Element Security Options

AAA

RADIUS

Secure Shell (SSH v2)

Secure Copy (SCP)

TACACS/TACACS+

Username/Password (Challenge and Response)

Bi-level Access Mode (Standard and EXEC Level)

Protection for Denial of Service attacks, such as TCP SYN or Smurf Attacks

Environmental

Operating Temperature: 0° C to 40° C (32° F to 104° F)

Relative Humidity: 5 to 90% at 40° C (104° F), non-condensing

Operating Altitude: 10,000 ft (3,000 m)

Storage Temperature: -25º C to 70º C (-13º F to 158° F)

Storage Humidity: 95% maximum relative humidity, non-condensing

Storage Altitude: 15,000 ft (4,500 m) maximum

Safety Agency Approvals

CAN/CSA-C22.2 No.60950-00/UL 60950—Third Edition, Safety of Information Technology Equipment

EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User’s Guide

EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre

Communication Systems

EN 60950 Safety of Information Technology Equipment

Electromagnetic Emission Certification

CSA 950 Electromagnetic Emission Certification

FCC Class A

EN 55022/CISPR-22 Class A/ VCCI Class A

ICES-003 Electromagnetic Emission

Immunity

EN 61000-3-2 Power Line Harmonics

EN 61000-4-2 ESD

EN 61000-4-3 Radiated Immunity

EN 61000-4-4 EFT

EN 61000-4-5 Surge

EN 61000-4-6 Low Frequency Common Immunity

EN 61000-4-11 Voltage Dips and Sags Generic: EN50082-1

ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD

Radiated: IEC 61000-4-3;3 V/m

EFT/Burst: IEC 61000-4-4;1.0 kV (power line), 0.5 kV (signal line)

Conducted: IEC 61000-4-6; 3 V

Environmental Regulatory Compliance

EU 2002/95/EC RoHS (with lead exemption)

EU 2002/91/EC WEEE

Warranty

1-year hardware

90-day software

Mounting Options

19 Universal EIA 310 (Telco) Rack or Tabletop

brocade bigiron rx series system specifications

System Max

@ 100 VAC

 

 

@ 200 VAC

 

 

@ -48 VDC

 

 

 

Current

Power

Thermal

Current

Power

Thermal

Current

Power

Thermal

 

Amps

Watts

Output

Amps

Watts

Output

Amps

Watts

Output

 

 

 

BTU/Hr

 

 

BTU/Hr

 

 

BTU/Hr

BigIron RX-32

N/A

N/A

N/A

57

11,353

38,746

237

11,353

38,746

BigIron RX-16

49

4,905

16,741

24

4,905

16,741

102

4,905

16,741

BigIron RX-8

24

2,417

8,249

12

2,417

8,249

50

2,417

8,249

BigIron RX-4

12

1,217

4,155

6

1,217

4,155

25

1,217

4,155