product features | CSDV Series Direct Vent Gas Stove |
PRODUCT SPECIFICATIONS
•This appliance has been certified for use with either natural or propane gas. See appropriate data plates.
•This appliance is not for use with solid fuels.
•The appliance is approved for bedroom or bedsitting room installations.
•The appliance must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in Canada.
•This appliance is mobile home approved.
•The appliance must be properly connected to a venting system.
•The appliance is not approved for closet or recessed installations.
•For alcove installation see “Clearances,” Page 9.
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are certi- fied without deration for elevations up to 4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local authorities having jurisdiction for installations at eleva- tions above 4,500 feet (1,370 m).
GAS pressures
| Natural | Propane (LP) |
Inlet Minimum | 4.5” w.c. | 11.0” w.c. |
Inlet Maximum | 10.5” w.c. | 13.0” w.c. |
Manifold Pressure | 3.5” w.c. | 10.0” w.c. |
58D6056
On/Off
Switch
FP2724
Optional
Remote
Receiver
Hi/Lo Knob
Pilot | Ignitor Box | |
Optional Blower | ||
Located Under | ||
| ||
Door | Right Front Leg | |
| ||
Figure 1 - |
| |
CSDV Cast Iron Stove Controls |
|
Gas Specifications & ORIFICE SIZE
|
| Max.Input | Min. Input |
|
|
Model | Fuel | BTU/h | BTU/h | Orifice Size | |
CSDV20NV | Nat. | 18.000 | 12,500 | #43 |
|
CSDV20PV | LP | 19,000 | 15,000 | #54 |
|
CSDV30NV | Nat. | 28,000 | 17,000 | #35 |
|
CSDV30PV | LP | 28,000 | 21,000 | #51 |
|
|
|
|
| Front | Rear |
CSDV40NV | Nat. | 33,000 | 26,000 | #46 | #43 |
CSDV40PV | LP | 33,000 | 30,000 | #57 | 1.45 mm |