product features

product features

CSDV Series Direct Vent Gas Stove

PRODUCT SPECIFICATIONS

This appliance has been certified for use with either natural or propane gas. See appropriate data plates.

This appliance is not for use with solid fuels.

The appliance is approved for bedroom or bedsitting room installations.

The appliance must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in Canada.

This appliance is mobile home approved.

The appliance must be properly connected to a venting system.

The appliance is not approved for closet or recessed installations.

For alcove installation see “Clearances,” Page 9.

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are certi- fied without deration for elevations up to 4,500 feet (1,370 m) above sea level.

For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at eleva- tions above 4,500 feet (1,370 m).

GAS pressures

 

Natural

Propane (LP)

Inlet Minimum

4.5” w.c.

11.0” w.c.

Inlet Maximum

10.5” w.c.

13.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

58D6056

On/Off

Switch

FP2724

Optional

Remote

Receiver

Hi/Lo Knob

Pilot

Ignitor Box

Optional Blower

Located Under

 

Door

Right Front Leg

 

Figure 1 -

 

CSDV Cast Iron Stove Controls

 

Gas Specifications & ORIFICE SIZE

 

 

Max.Input

Min. Input

 

 

Model

Fuel

BTU/h

BTU/h

Orifice Size

CSDV20NV

Nat.

18.000

12,500

#43

 

CSDV20PV

LP

19,000

15,000

#54

 

CSDV30NV

Nat.

28,000

17,000

#35

 

CSDV30PV

LP

28,000

21,000

#51

 

 

 

 

 

Front

Rear

CSDV40NV

Nat.

33,000

26,000

#46

#43

CSDV40PV

LP

33,000

30,000

#57

1.45 mm

Page 5
Image 5
Monessen Hearth CSDV20SNV, CSDV40NDV product features, Product Specifications, High Elevations, GAS pressures, 58D6056

FAQ

What type of gas can I use with the Monessen Hearth CSDV Series Direct Vent Gas Stove?

This appliance has been certified for use with either natural or propane gas.

Is the Monessen Hearth CSDV Series Direct Vent Gas Stove approved for bedroom installations?

Yes, this appliance is approved for bedroom or bedsitting room installations.

What are the recommended gas pressures for the Monessen Hearth CSDV Series Direct Vent Gas Stove?

For natural gas, the recommended inlet pressure is 4.5 w.c. to 10.5 w.c. For propane LP, the recommended inlet pressure is 11.0 w.c. to 13.0 w.c.