IMPORTANT SAFETY INFORMATION

15.This appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical Code, ANS/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

16.Do not obstruct the flow of combustion and ventilation air in any way. Provide adequate clearances around air openings into the combustion chamber along with adequate accessibility clearance for servicing and proper operation.

17.When the appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, you must set appliance on a metal or wood panel or hearth pad extending the full width and depth of the appliance.

18.Do not use stove if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit.

19.Do not operate stove if any log is broken.

20.Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this stove.

21.Do not operate the stove with glass door removed, cracked, or broken.

22.Massachusetts only refer to Page 46 for further infor- mation.

!WARNING

HOT GLASS WILL

CAUSE BURNS.

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER ALLOW CHILDREN

TO TOUCH GLASS.

Code Approval

Direct Vent type appliances draw all combustion air from outside of the dwelling through the vent pipe.

These appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as follows:

LISTED VENTED GAS FIREPLACE HEATER

TESTED TO: ANSI Z21.88-2009 / CSA 2.33-2009 STANDARDS

58D6056

Page 4
Image 4
Monessen Hearth CSDV20DNV manual Code Approval, CSDV Series Direct Vent Gas Stove, Important Safety Information, 58D6056

FAQ

What are the safety guidelines for installing the CSDV Series Direct Vent Gas Stove?

The appliance must be electrically grounded, not obstruct the flow of combustion and ventilation air, and be installed on a metal or wood panel if on combustible flooring.

Can the stove be operated with broken logs?

No, the stove should not be operated if any log is broken.

What standards does the appliance comply with?

The stove complies with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada.