Monessen Hearth CSDV20DLP, CSDV40NDV Lighting pilot for the first time, Pilot, initial lighting

Models: CSDV20SLP CSDV40SLP CSDV40NDV CSDV20DLP CSDV20DNV CSDV30SNV CSDV40DLP CSDV40SNV CSDV30DLP CSDV30DNV CSDV20SNV CSDV30SLP

1 44
Download 44 pages 11.36 Kb
Page 30
Image 30
 Lighting pilot for the first time

CSDV Series Direct Vent Gas Stove

OPERATING INSTRUCTIONS

initial lightingleak testing Lighting pilot for the first time WARNING WARNINGLighting pilot

initial lighting

Purge air from the supply line as follows:

Open main shutoff valve.

Unscrew main pressure test point.

Leave inlet test screw open until gas comes in.

When gas is flowing, tighten inlet screw immediately.

leak testing

You may check for gas leaks with the following methods only:

Soap and water solution

An approved leak testing spray

Electronic sniffer

WARNING WARNING

If using a soap and water solutiong to test for leaks, DO NOT spray solution onto control body.

Never use an open flame to check for gas leaks.

Check for gas leaks in each of the following locations:

• Pipe from the gas supply line connection to the gas valve

Burner connections

• Field made joints / gas shutoff valve

Pilot

Factory made joints

• Each joint or connection

All joints on valve and control body

WARNING

Lighting pilot PILOT

The control has an interlock device that does not allow the lighting of the stove up to the moment the safety device of the flame has not interrupted the gas flow. After that period of time (when the magnet is closed), it is possible to start the lighting operation.

The gas control knob is designed to be operated by hand. DO NOT use any tools during this operation. Damaged knobs may result in serious injury.

1.Depress and turn knob counterclockwise Manual background to pilot position.

2.Depress fully and hold pilot gas knob. The electronic ignitor will automatically ignite the pilot. Keep knob fully depressed for a few sec- onds. Release and check that pilot continues to burn.

If the pilot does not stay lit, repeat Steps 1 and 2.

 

O

T

N

 

O

 

L

 

I

 

P

 

 

F

 

F

 

O

PILOT

Figure 42 -

Pilot Position

30

58D6056

Page 30
Image 30
Monessen Hearth CSDV20DLP manual Lighting pilot for the first time, Pilot, initial lighting, leak testing, Warning Warning

FAQ

How do I purge air from the supply line?

To purge air from the supply line, open the main shutoff valve and unscrew the main pressure test point. Leave the inlet test screw open until gas comes in, then tighten the inlet screw immediately.

What methods can I use to check for gas leaks?

You may use a soap and water solution, an approved leak testing spray, or an electronic sniffer to check for gas leaks.

How do I light the pilot?