iNSTALLATION INFORMATION

iNSTALLATION INFORMATION

CSDV Series Direct Vent Gas Stove

STOVE LOCATION

Plan for the installation of your stove. This includes deter- mining where the unit is to be installed, the vent configura- tion to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspections.

The following factors should be taken into consideration:

This stove should have sufficient access for its safe operation and maintenance.

Locate a position where the flue system of the stove can be properly installed without damaging the integrity of the building. e.g. cutting wall or ceiling joist (example: load-bearing framing members).

When the appliance is installed directly on carpeting, tile or other combustible material other than wood floor- ing, you must set appliance on a metal or wood panel extending the full width and depth of the appliance.

Check stove and flue system clearance requirements.

Locate the stove where it can be accessed by a gas supply line.

Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation and comfort.

The flow of combustion and ventilation air must not be obstructed.

Minimum clearances to combustibles, side-wall, ceiling, woodwork, and windows must be maintained. Page 9, Figure 4

This stove may be installed along a wall, across a corner, or use an exterior chase. Refer to Figure 3 for suggested locations.

Location should be out of high traffic areas and away from furniture and draperies due to heat from appli- ance.

Never obstruct the front opening of the stove.

Do not install in the vicinity where gasoline or other flammable liquids may be stored.

Vent pipe routing. See Venting section found in this manual for allowable venting configurations.

These units can be installed in a bedroom. See National Fuel Gas Code ANSI Z233.1/NFPA 54 (current edition), the Uniform Mechanical Code (current edition), and Local Building Codes for specific installation require- ments.

NOTE: If this unit is installed in a mobile home it must be bolted securely to the floor with leg bolts.

NOTE: Stoves work without any electrical supply.

Figure 3 -

ST1127

Possible Stove Locations

 

58D6056

Page 7
Image 7
Monessen Hearth CSDV30DLP, CSDV40NDV iNSTALLATION INFORMATION, Stove Location, CSDV Series Direct Vent Gas Stove, 58D6056

FAQ

What are the clearance requirements for the stove?

The minimum clearances to combustibles, side-wall, ceiling, woodwork, and windows must be maintained. Refer to Page 9, Figure 4 for more details.

Can the stove be installed in a bedroom?

Yes, these units can be installed in a bedroom. Refer to National Fuel Gas Code ANSI Z233.1/NFPA 54 current edition for specific installation requirements.

Does the stove require electrical supply?

No, stoves work without any electrical supply.