C.2 Lighting Procedures
1. Broiler is | 2. Gas valve is | 3. Turn ventilation |
centered under | open when | system on |
hood and | handle is in line |
|
plugged in | (parallel to) the |
|
| pipe |
|
WARNING
THE VENTILATION SYSTEM MUST BE ON AT ALL TIMES DURING BROILER OPERATION. OPERATING BROILER WITHOUT PROPER VENTILATION IS A SEVERE FIRE HAZARD.
MAIN CHAMBER IGNITION
Turn the MAIN POWER SWITCH (a) on. Starting with the MAIN CHAMBER RED PILOT BUTTONS,
1 press and hold the LOWER BUTTON FIRST (b) for a 30 seconds after the pilot has lit. Then press the
UPPER PILOT BUTTON (c) for 30 seconds after the pilot has lit.
c
b
After releasing red pilot buttons; check GAS PRES- |
|
|
|
|
|
| |
SURE GAUGE (a) reading. Gauge should read 4”. If |
|
|
|
not, follow troubleshooting tips in section E of this | a |
|
|
manual. Verify that main chamber burners - upper |
|
| |
|
|
| |
2 and lower - have lit. |
|
|
|
|
|
|
|
FLEX CHAMBER IGNITION
Move to the FLEX CHAMBER RED PILOT | a |
| |
BUTTON (a), push and hold for 30 seconds after |
|
the pilot has lit. Release, and verify that the burners |
|
have lit, and that the GAS PRESSURE GAUGE (b) |
|
3 reads 4”. |
|
PILOTS MUST BE LIT WITHIN 5 MINUTES; IF YOU EXCEED 5 MINUTES, PRESS THE RESET BUTTON NEXT TO THE ON/OFF SWITCH AND REPEAT IGNITION PROCEDURES. IF REIGNI- TION FAILS, COMPLETELY SHUT OFF THE BROILER, WAIT 5 MINUTES AND REPEAT THE IGNITION PROCEDURES.
b
Reset Button
12Nieco Corporation - Model 9025