B.8 Restraining Device Installation and Use
This high strength restrainer is to be used with all moveable (castered) appliances. It fully complies with American Gas Association requirements. References: Z21.69, Z83.11, and Z21.41 with current revisions. Installation is quick and positive. In Canada, device is in accordance with CAN
Correct length for any appliance is simply a matter of loosening two adjuster clips (1) and
Restrainer is made of heavy duty steel cable, with a strong scissor hood (2) at one end, and an equally strong
spring hook (3) at the other. Cotter pin (4) is supplied to secure the installation. For proper attachment to the broiler,
use the supplied hardware to attach the device to the holes in the shear plate of the broiler stand.
NOTE: If disconnection of the restraint is necessary, reconnect the restraint after the appliance has been
returned to its originally installed position.
B.9 Electrical Connection
Power requirements are stated on the unit nameplate and must be connected accordingly. This appli- ance, when installed must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable. Before starting broiler, tighten all electrical connections in control box. An electrical wiring diagram can be found inside the control box.
Note: Disconnect power before servicing. |
|
|
P/N 11960 - 6ft Male Power Cord | P/N 11961 - 3ft Female Power Cord |
|
30A 3Ø 250V | 30A 250V |
NOTE: If overhead power supply connection is not used; use power supply receptacle attached
to the steamer table. The power supply receptacle will be supplied by your KES.
B.10
Be sure that all parts are installed in the proper location:
❏Ventilation is turned on
❏Broiler is plugged in
❏Gas line is connected
9 | Nieco Corporation - Model 9025 |