B.4 Hood Requirements

This appliance must be installed under a ventilation hood of adequate size and the following minimum capacity:

Model

SCFM

9025

1000

Do not obstruct the flow of combustion and ventilation air. An adequate air supply must be available for safe and proper operation.

B.5 Clearance

For proper installation the minimum clearance from combustible and non-combustible construction must be 305 mm (12”) from the back and 305 mm (12”) from the front of the machine. Keep appliance area free from combustibles.

To facilitate disassembly and service of the unit a minimum of 610 mm (24”) should be allowed on the control panel (feed end) of the broiler, as well as in front and back of the broiler.

* 12” (305mm) Minimum, preferably 610 mm (24”) or more for service. Location clearances are from walls of broiler height.

7

Nieco Corporation - Model 9025