Broilmaster SBB 2804 owner manual GAS Conversion to Liquid Propane GAS

Models: SBB 2804

1 24
Download 24 pages 19.02 Kb
Page 18
Image 18

GAS CONVERSION TO LIQUID PROPANE GAS

A conversion kit to liquid propane (LP) gas is included with your grill.

1.Remove cooking grids and flame tamer from grill.

2.Use allen wrench supplied in conversion kit to remove control knobs.

3.Remove control panel (4 Phillips screws).

Figure 18

4.Use a 7mm socket or wrench to remove all natural gas orifices marked 53 from gas valves.

5.Install LP gas orifices marked 1.02 into gas valves. Apply pipe compound to threads on orifices prior to installation.

6.Attach left side of control panel to grill with two (2) Phillips screws from Step 3. Carefully insert left burner orifice into left burner. Continue to carefully insert the remaining orifices into the burners. Attach right side of control panel to grill with two

(2) Phillips screws from Step 3.

7.The low input adjustment screws are located inside the main burner valve stems. Use small screwdriver supplied in conver- sion kit to turn each adjustment screw clockwise 1/4 turn (90 degrees).

The valve stem that is second from the left side of the grill is the rotisserie valve stem and it will not be adjusted.

8.Remove rotisserie burner back cover (5 Phillips screws - four on the back and one on inside top of the back of the grill).

9.Use a 14mm wrench or adjustable wrench to remove natural gas rotisserie orifice marked 1.51 from orifice fitting.

10.Install LP gas rotisserie orifice marked 1.02 into orifice fitting. Apply pipe compound to threads on orifice prior to installa- tion.

11.Remove the flexible gas line from manifold.

12.Connect the hose and regulator (no included) to manifold with an adjustable wrench. Please contact your dealer to order the necessary parts for your Broilmaster grill.

13.Attention: Before lighting your grill check all gas connections including the adjustment screws in valve stems for gas leaks with a soapy water mixture.

Caution: Do not use the grill if a gas leak is detected until gas leak is corrected. If a gas leak can not be stopped, do not use

grill. You must contact a qualified repair person.

14.Replace back panel (5 Phillips screws from step 8).

15.Replace all control knobs with allen wrench.

16.Apply the completed conversion label adjacent to the rating plate label on the rear panel of the grill.

17.Ignite burners on grill and observe flame pattern. If flame is yellow in color or flame is lifting off burner, the air shutter on burners will require adjustment.

18.Turn OFF (but do NOT remove) LP gas supply to grill.

19.Loosen (but do NOT remove) two (2) Phillips screws at end of each burner. Lift upward and pivot burner out of grill.

20.Loosen Phillips screw at air shutter. Air shutter for LP gas should have about 1/8” opening. Open air shutter for a yellow flame or close air shutter for a lifting flame. Tighten Phillips screw at air shutter.

21.Replace burners into grill. Tighten two (2) Phillips screws at end of each burner.

22.Ignite burners on grill to verify burner flame characteristics.

Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1. In Canada, installation shall be in accordance with CAN/CGA-B149.1 Natural Gas Installation Code, and local codes where applicable. Contact your local gas company for code regulations, recommended pro- cedures, and the installation of your grill’s gas supply line.

Page 18

SBB00104-1-1107

Page 18
Image 18
Broilmaster SBB 2804 owner manual GAS Conversion to Liquid Propane GAS