OPERATION - PROPANE & NATURAL GAS GRILLS

Checking for Gas Leaks

Check for gas leaks every time you connect your Broilmaster propane gas grill to a Propane gas cylinder, when a connected cylinder has not been used recently, or when either a natural or propane grill is being used for the first time.

Caution: Do not use an open flame when checking for leaks. Checking for leaks with an open flame may lead to a fire or explosion, resulting in property damage or personal injury.

To check for gas leaks:

1.Use dish washing liquid and a little water to make a soapy solution.

2.Turn OFF the knob on the control panel.

3.Turn ON the gas at the supply or cylinder. A hissing sound indicates a leak. Turn OFF the gas and repair the leak.

4.Apply the soapy water solution to all gas connections.

5.Look for bubbles. Bubbles indicate a leak.

6.If there are bubbles turn OFF the gas and repair the leak.

7.Turn the gas back ON and repeat the above procedures until all leaks are repaired.

Air Shutter Adjustment

The burner (venturi) tube air shutter is preset at the factory so that after five minutes the burner flames are blue with well defined cones. If, after five minutes the flame is yellow, or there is a gap between the burner and the flame, adjust the burner (venturi) tube air shutter as follows:

1.Turn gas OFF and let the burner cool.

2.Beneath the control panel you can access the air shutter(s) which are located on the end of the burner tubes.

3.Loosen shutter set screw

4.Close the air shutter to the minimum opening.

5.Light the burner, wait five minutes and then carefully open the air shutter until the flame is blue and well defined.

6.Retighten the set screw.

Operating Instructions

Before each use, inspect all hoses. If it is evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to using your Broilmaster grill. Call your local Broilmaster dealer for a replacement.

Using the Ignitor

Caution: If a burner fails to light after 5 seconds, turn the burner OFF for 5 minutes, to allow the gas to clear, then try again.

Note: Each burner must be lit individually.

1.Turn knob on the grill CLOCKWISE to the OFF posi- tion.

2.Turn ON gas at the source.

3.With the grill lid open, push and turn the burner control knob COUNTERCLOCKWISE to Hi.

4.Push and hold the ignitor button until the burner lights (approximately 5 seconds).

5.If a burner does not light, turn OFF all gas and refer to the Troubleshooting section of this manual.

6.Repeat steps 3 through 5 for other burner.

Using Matches

Caution: If a burner fails to light after 5 seconds, turn the burner OFF for 5 minutes, to allow the gas to clear, then try again.

Note: Each burner must be lit individually.

1.Turn knob on the grill CLOCKWISE to the OFF posi- tion.

2.Turn ON gas at the source.

3.Open the grill lid.

4.Insert a burning long wooden match through the lighter hole on either side of the grill. See Figure 20.

5.Turn the burner control knob COUNTERCLOCKWISE to HI.

6.If a burner does not light, turn OFF all gas and refer to the Troubleshooting section of this manual.

7.Repeat steps 3 through 6 for other burner.