STEAM BOILER DIMENSIONS in inches (cm)

 

 

 

 

 

 

 

 

 

 

 

A

 

 

B

C

D

E

 

 

F

 

G

 

 

H

 

I

J

 

K

 

Boiler

Length

 

 

Flue

Flue

Overall

Gas Train

 

Supply

Feed

Width

Min. Tube

Height

 

Floor to

 

Model

of

 

 

Connection

 

 

Nozzle

Outside

Removal

Over

 

Flow

 

 

Location

Size

Length

 

 

Conn.

 

 

Number

Jacket

 

 

 

 

 

 

(Approx.)

 

15 psi

 

150 psi

 

Jacket

Clearance

Jacket

 

Nozzle

 

CLM-120-S

5011/16

2511/32

10

7811/16

11/4 NPT

 

6 FLG

 

3 NPT

11/2 NPT

383/8

30

797/16

 

825/8

 

(128.74)

(64.37)

(25.40)

(199.86)

(3.18)

 

 

(15.24)

 

(7.62)

(3.81)

(97.47)

(76.2)

(201.76)

 

(209.86)

 

 

 

 

 

 

 

CLM-150-S

5911/16

2927/32

12

8711/16

11/2 NPT

 

6 FLG

 

3 NPT

11/2 NPT

383/8

30

797/16

 

825/8

 

(151.60)

(75.80)

(30.48)

(222.72)

(3.81)

 

 

(15.24)

 

(7.62)

(3.81)

(97.47)

(76.2)

(201.76)

 

(209.86)

 

 

 

 

 

 

 

CLM-180-S

691/8

349/16

14

971/8

2 NPT

 

6 FLG

 

3 NPT

11/2 NPT

383/8

30

797/16

 

825/8

 

(175.57)

(87.78)

(35.56)

(246.69)

(5.08)

 

 

(15.24)

 

(7.62)

(3.81)

(97.47)

(76.2)

(201.76)

 

(209.86)

 

 

 

 

 

 

 

CLM-210-S

783/8

393/16

14

1063/8

2 NPT

 

6 FLG

 

3 NPT

11/2 NPT

383/8

30

797/16

 

825/8

 

(199.07)

(99.53)

(35.56)

(270.19)

(5.08)

 

 

(15.24)

 

(7.62)

(3.81)

(97.47)

(76.2)

(201.76)

 

(209.86)

 

CLM-240-S

88

44

16

116

2 NPT

 

6 FLG

 

3 NPT

11/2 NPT

383/8

30

797/16

 

825/8

 

(223.52)

(111.76)

(40.64)

(294.64)

(5.08)

 

 

(15.24)

 

(7.62)

(3.81)

(97.47)

(76.2)

(201.76)

 

(209.86)

 

 

 

 

 

 

 

CLM-270-S

97

481/2

16

125

2 NPT

 

6 FLG

 

3 NPT

11/2 NPT

383/8

30

797/16

 

825/8

 

(246.38)

(123.19)

(40.64)

(317.50)

(5.08)

 

 

(15.24)

 

(7.62)

(3.81)

(97.47)

(76.2)

(201.76)

 

(209.86)

 

 

 

 

 

 

 

CLM-300-S

1065/8

533/16

16

1345/8

21/2 NPT

 

6 FLG

 

3 NPT

11/2 NPT

383/8

30

797/16

 

825/8

 

(270.82)

(135.41)

(40.64)

(341.94)

(6.35)

 

 

(15.24)

 

(7.62)

(3.81)

(97.47)

(76.2)

(201.76)

 

(209.86)

 

 

 

 

 

 

WATER BOILER DIMENSIONS in inches (cm)

 

A

B

C

D

E

F

G

H

I

J

K

Boiler

Length

Flue

Flue

Overall

Gas

Supply

Return

Width

Min. Tube

Height

Floor to

Model

of

Train

Outside

Removal

Over

Flow

Location

Size

Length

Nozzle

Nozzle

Number

Jacket

Connection

Jacket

Clearance

Jacket

Nozzle

 

 

 

 

 

CLM-120-W

5011/16

255/16

10

7811/16

11/4 NPT

3 NPT

3 NPT

345/8

30

721/16

763/16

(128.74)

(64.29)

(25.40)

(199.86)

(3.18)

(7.62)

(7.62)

(87.94)

(76.2)

(180.03)

(193.51)

 

CLM-150-W

5911/16

2913/16

12

8711/16

11/2 NPT

3 NPT

3 NPT

345/8

30

721/16

763/16

(151.60)

(75.72)

(30.48)

(212.72)

(3.81)

(7.62)

(7.62)

(87.94)

(76.2)

(180.03)

(193.51)

 

CLM-180-W

691/8

349/16

14

971/8

2 NPT

3 NPT

3 NPT

345/8

30

721/16

763/16

(175.57)

(87.78)

(35.56)

(246.69)

(5.08)

(7.62)

(7.62)

(87.94)

(76.2)

(180.03)

(193.51)

 

CLM-210-W

783/8

393/16

14

1063/8

2 NPT

3 NPT

3 NPT

345/8

30

721/16

763/16

(199.07)

(99.53)

(35.56)

(270.19)

(5.08)

(7.62)

(7.62)

(87.94)

(76.2)

(180.03)

(193.51)

 

 

 

 

 

 

 

 

 

 

 

 

 

CLM-240-W

88

44

16

116

2 NPT

3 NPT

3 NPT

345/8

30

721/16

763/16

(223.52)

(111.76)

(40.64)

(294.64)

(5.08)

(7.62)

(7.62)

(87.94)

(76.2)

(180.03)

(193.51)

 

CLM-270-W

97

481/2

16

125

2 NPT

3 NPT

3 NPT

345/8

30

721/16

763/16

(246.38)

(123.19)

(40.64)

(317.50)

(5.08)

(7.62)

(7.62)

(87.94)

(76.2)

(180.03)

(193.51)

 

CLM-300-W

1065/8

533/16

16

1345/8

21/2 NPT

3 NPT

3 NPT

345/8

30

721/16

763/16

(270.82)

(135.41)

(40.64)

(341.91)

(6.35)

(7.62)

(7.62)

(87.94)

(76.2)

(180.03)

(193.51)

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifications subject to change without notice. Consult factory to consult on other boiler options.

Bryan Steam LLC Leaders Since 1916

783 N. Chili Ave., Peru, Indiana 46970 U.S.A.

Phone:765-473-6651 • Internet:www.bryanboilers.com

Fax: 765-473-3074E-mail:bryanboilers@iquest.net

Form No. 1930

©2005 Bryan Steam LLC

Printed in USA

 

 

45-6832

Page 4
Image 4
Bryan Boilers manual Bryan CLM Series Steam & Hot Water Boilers

CLM Series specifications

The Bryan Boilers CLM Series represents a cutting-edge advancement in the realm of commercial water-tube boilers, designed to meet the rigorous demands of various industrial applications. Known for its reliability and efficiency, this series is particularly well-suited for those seeking a high-performance, compact boiler solution.

One of the main features of the CLM Series is its modular design, which allows for easy transportation and installation. The compact structure provides flexibility in space-constrained environments while ensuring optimal performance. This modularity also enables quick scalability, accommodating the changing needs of a business without the hassle of extensive modifications.

Another standout characteristic of the CLM Series is its enhanced efficiency. The series employs a unique combustion process that maximizes fuel utilization. This efficiency translates into significant cost savings for users, as the reduced fuel consumption leads to lower operating expenses. Moreover, the CLM boilers are designed to operate effectively with a range of fuel types, including natural gas, propane, and biofuels, making them versatile for diverse operational contexts.

The CLM Series also employs advanced control technologies. The integrated microprocessor controls enhance operational precision, allowing for adaptive response to varying load conditions. These intelligent controls ensure optimal combustion efficiency, precise temperature management, and minimized emissions. This aligns with increasingly stringent environmental regulations, allowing businesses to operate sustainably without sacrificing performance.

In terms of safety and reliability, the CLM Series is equipped with multiple safety features, including flame monitoring systems and pressure controls. These safety mechanisms work in concert to provide peace of mind for operators while minimizing the risks associated with boiler operations.

Another notable characteristic of the CLM Series is its impressive lifespan. Built with high-quality materials and robust engineering, these boilers are designed to endure heavy-duty usage across various applications. This durability not only reduces the frequency of replacement but also enhances overall system reliability.

In summary, the Bryan Boilers CLM Series stands out in the market as an efficient, reliable, and versatile solution for commercial and industrial heating needs. With its modular design, advanced control technologies, fuel flexibility, and a strong emphasis on safety and durability, the CLM Series is positioned as a leading choice for businesses seeking sustainable and high-performance boiler solutions.