Bryan Boilers Flexible Water Tube Boilers manual Bryan, We have a boiler for, RW Series

Models: Flexible Water Tube Boilers

1 8
Download 8 pages 39.31 Kb
Page 2
Image 2
 BRYAN®

Forced draft gas, oil and dual-fuel boilers...hot water and steam BRYAN®

Forced draft gas, oil and dual-fuel boilers...hot water and steam

The Exclusive Bryan “Flexible Water Tube” Design

The “Flexible Water Tube” design of the Bryan Boiler provides for extremely fast, natural internal circulation, resulting in maximum heat transfer and operating efficiency. Dependency on external pumps is eliminated. The unique flexible bent tube design prevents all possible damage from thermal shock and related problems. Bryan Flexible Tubes are easily removable and replaceable, allowing for quick and simple boiler maintenance. Boiler room dimensions are minimized, as little space is required for tube withdrawal — a real savings. Don’t be misled by claims of “or-equal” or “similar design.” Only Bryan Boilers feature the unique, original “Flexible Water Tube” design.

We have a boiler for

Water Boiler

RW2100-W-FDGO

(527 Boiler HP)

RW Series

Hot water and steam* boilers with forced draft gas, oil or dual-fuel firing. Bryan’s largest boilers for the big heating requirements. Sizes from 8,500 MBH to 21,000 MBH input (200 BHP to 527 BHP output).

*Bryan steam boilers are available as standard for 15 psi MWP or 150 psi MWP. Also available for steam pressures up to 300 psi.

Quick Reference Selection Chart

Bryan

 

Size Ranges

 

Boiler Type

 

Energy Source

 

Low Nox

Knockdown

Boiler

 

 

BHP

Hot

 

Forced Draft

Forced Draft

Dual-Fuel

Atmos.

 

Package

Series

MBH Input

MBH Output

Output

Water

Steam

Gas

Oil

(Gas/Oil)

Gas

Electric

Option

Option

DR

250-850

200-680

6-21

X

X

X

X

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AB

900-3,000

720-2,400

21-75

X

X

X

X

X

 

 

X

X

HE-AB

900-3,000

765-2,550

23-76

X

 

X

 

 

 

 

X

X

 

 

 

 

 

 

 

 

 

 

 

 

 

RV

3,500-8,000

2,800-6,400

84-201

X

X

X

X

X

 

 

X

X

HE-RV

3,500-8,000

2,975-6,800

89-203

X

 

X

 

 

 

 

X

X

 

 

 

 

 

 

 

 

 

 

 

 

 

RW

8,500-21,000

6,800-16,800

200-527

X

X

X

X

X

 

 

X

 

CLM

1,200-3,000

960-2,400

29-73

X

X

X

X

X

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

HE-CLM

900-3,000

765-2,550

23-76

X

 

X

 

 

 

 

 

X

CLM

900-3,000

720-2,400

21-72

X

X

 

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

K

3,500-6,500

2,800-5,200

84-155

X

X

 

 

 

X

 

 

X

BE

30KW-330KW

98-1,081

3-39

X

X

 

 

 

 

X

X**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BH

60KW-3,000KW

196-9,828

6-300

X

X

 

 

 

 

X

X**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** There are no emissions from electric boilers.

2

Page 2
Image 2
Bryan Boilers Flexible Water Tube Boilers manual We have a boiler for, The Exclusive Bryan “Flexible Water Tube” Design