Bryant 165A manual Physical Data, Vapor Line Sizing And Cooling Capacity Loss

Models: 165A

1 40
Download 40 pages 38.33 Kb
Page 3
Image 3
PHYSICAL DATA

PHYSICAL DATA

UNIT SIZE SERIES

018---B

024---B

030---B

 

036---B

 

042---B

048---B

060---B

Operating Weight lb (kg)

186 (89.4)

198 (89.8)

258 (117.0)

 

259 (117.5)

 

320 (145.1)

326 (147.9)

330 (149.7)

Shipping Weight lb (kg)

228 (103.4)

229 (103.9)

298 (135.2)

 

299 (135.6)

 

355 (161.0)

361 (163.7)

365 (165.6)

Compressor Type

 

 

 

 

Scroll

 

 

 

REFRIGERANT

 

 

 

Puron(R---410A)

 

 

 

Control

 

 

TXV (PuronHard Shutoff)

 

 

Charge lb (kg)

5.28 (2.39)

5.66 (2.57)

10.77 (4.89)

 

10.03 (4.55)

 

10.80 (4.90)

11.40 (5.17)

13.17 (5.97)

COND FAN

 

 

Forward Swept, Propeller Type, Direct Drive

 

 

Air Discharge

 

 

 

 

Vertical

 

 

 

Air Qty (CFM)

2140

2140

2595

 

3265

 

3265

3673

3673

Motor HP

1/12

1/12

1/10

 

1/6

 

1/6

1/4

1/4

Motor RPM

800

800

800

 

800

 

800

800

800

COND COIL

 

 

 

 

 

 

 

 

 

Face Area (Sq ft)

16.08

16.08

18.30

 

18.30

 

24.40

24.40

24.40

Fins per In.

25

25

20

 

20

 

20

20

20

Rows

1

1

2

 

2

 

2

2

2

Circuits

4

4

6

 

6

 

8

8

8

VALVE CONNECT. (In. ID)

 

 

 

 

 

 

 

 

 

Vapor

5/8

5/8

3/4

 

3/4

 

7/8

7/8

7/8

Liquid

 

 

 

3/8

 

 

 

 

REFRIGERANT TUBES (In. OD)

 

 

 

 

 

 

 

 

 

Rated Vapor*

5/8

5/8

3/4

 

3/4

 

7/8

7/8

1---1/8

Liquid

 

 

 

3/8

 

 

 

 

*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. NOTE: See unit Installation Instruction for proper installation.

165A

VAPOR LINE SIZING AND COOLING CAPACITY LOSS

LONG LINE APPLICATION: An application is considered ”Long line” when the total equivalent tubing length exceeds 80 ft. (24.38 m) or when there is more than 20 ft. (6.09 m) vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is up to 250 ft. (76.2 m). The maximum

vertical separation is 200 ft. (60.96 m) when outdoor unit is above indoor unit, and up to 80 ft. (24.38 m) when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Longline Application Guideline for required piping and system modifications. Also, refer to the table below for the vapor tube diameters based on the total length to minimize the cooling capacity loss.

 

 

 

 

 

 

 

Cooling Capacity Loss (%)

 

 

 

 

Unit Nomi-

Maximum

Vapor Line

 

 

 

Total Equivalent Line Length ft. (m)

 

 

 

 

Liquid Line

Standard

 

 

 

 

 

 

 

 

nal Size

Diameters

 

Long Line Application Requires Accessories

 

 

Diameters

Application

 

 

 

(Btuh)

(In. OD)

 

 

 

 

 

 

 

 

 

(In. OD)

 

 

 

 

 

 

 

 

 

 

 

 

 

26---50

51---80

81---100

101---125

126---150

151---175

176---200

201---225

226---250

 

 

 

 

 

 

 

 

(7.9---15.2)

(15.5---24.4)

(24.7---30.5)

(30.8---38.1)

(38.4---45.7)

(46.0---53.3)

(53.6---61.0)

(61.3---68.6)

(68.9---76.2)

 

18000

 

1/2

1

2

3

4

6

7

8

9

10

 

1 Stage

3/8

 

5/8

0

0

1

1

1

2

2

3

3

 

Puron AC

 

 

24000

 

5/8

0

1

1

2

3

3

4

4

5

 

1 Stage

3/8

3/4

0

0

0

0

1

1

1

1

1

 

Puron AC

 

7/8

0

0

0

0

0

0

0

0

0

 

30000

 

5/8

1

2

3

3

4

5

6

7

8

 

1 Stage

3/8

3/4

0

0

1

1

1

2

2

2

3

 

Puron AC

 

7/8

0

0

0

0

1

1

1

1

1

 

36000

 

5/8

1

2

4

5

6

8

9

10

12

 

1 Stage

3/8

3/4

0

1

1

2

2

3

3

4

4

 

Puron AC

 

7/8

0

0

0

0

1

1

1

2

2

 

42000

 

3/4

0

1

2

2

3

4

4

5

6

 

1 Stage

3/8

7/8

0

0

1

1

1

2

2

2

3

 

Puron AC

 

1 1/8

0

0

0

0

0

0

0

0

0

 

48000

 

3/4

0

1

2

3

4

5

5

6

7

 

1 Stage

3/8

7/8

0

0

1

1

2

2

2

3

3

 

Puron AC

 

1 1/8

0

0

0

0

0

0

0

1

1

 

60000

 

3/4

1

2

4

5

6

7

9

10

11

 

1 Stage

3/8

7/8

0

1

2

2

3

4

4

5

5

 

Puron AC

 

1 1/8

0

0

0

1

1

1

1

1

1

 

Applications

in this area are

long line. Accessories are required as shown recommended on Long Line Application Guidelines

 

 

 

Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit

See Long Line Applica-

 

tion Guidelines

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Page 3
Image 3
Bryant 165A manual Physical Data, Vapor Line Sizing And Cooling Capacity Loss