ACCESSORY THERMOSTATS

THERMOSTAT / SUBBASE

DESCRIPTION

 

 

 

PKG.

 

 

 

 

 

 

 

 

T6---

PRH ---

01

 

Programmable Thermidistat

 

 

T6---

NRH ---

01

 

Non ---programmable Thermidistat

 

 

T2---

PHP---

01

 

Legacy Line Programmable HP Stat

 

 

T2---

NHP---

01

 

Legacy Line Non ---programmable HP Stat

 

 

TSTATBBPRH01---

B*

---Thermidistatt Control — Non Programmable/Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC,

HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)

 

 

 

 

 

 

TSTATBBPHH01---

B*

---HybridHeatt (Dual Fuel) Thermostat — Auto Changeover, 7 Day Programmable, °F/°C, Includes Outdoor Sensor

(TSTATXXSEN01---B)

 

 

 

 

 

 

 

 

TSTATBBPHP01---

B

Thermostat — Auto Changeover, 7---Day Programmable, °F/°C, 2

---Stage Heat, 1

---Stage Cool

TSTATBBNHP01---

C

Thermostat — Auto Changeover, Non ---Programmable, °F/°C, 2---

Stage Heat, 1---

Stage Cool

TSTATBBSHP01

 

---Standard Programmable Thermostat—Manual Changeover, 5 2 Day Programmable, °F/°C, 1---Stage Heat/ 1---Stage Cool

TSTATBBBHP01*

--- B

------Builder’s Thermostat — Heat Pump, Non Programmable, °F/°C, 2 Stage Heat, 1---Stage Cool, Manual Changeover

TSTATXXSEN01---

B**

Outdoor Air Temperature Sensor

 

 

TSTATXXNBP01

 

Backplate for Non ---Programmable Thermostat

 

 

TSTATXXPBP01

 

Backplate for Programmable Thermostat and Thermidistatt Control

 

TSTATXXSBP01

 

Backplate for Standard Programmable Thermostat

 

 

TSTATXXBBP01

 

Backplate for Builder’s Thermostat

 

 

TSTATXXCNV10{

 

Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack

 

 

* Do not use in zoning heat pump

applications.

 

 

** Outdoor temperature sensor is an accessory for all Bryant electronic thermostats, except the non ---

programmable air conditioner version and builder;s

thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the HybridHeatt (dual fuel) thermostat.

{ Thermostat conversion kit is a 24---vac accessory that can turn a 4---wire thermostat application into a 5---wire application. This kit can also be used to replace a broken thermostat wire, or add an extra wire when needed.

The outdoor air temperature sensor is included with the Thermidistat Control and HybridHeatt (dual fuel) thermostat.

ACCESSORY USAGE GUIDELINE

 

REQUIRED FOR LOW--- AMBIENT

REQUIRED FOR

REQUIRED FOR

Accessory

COOLING APPLICATIONS

LONG LINE APPLICATIONS*

SEA COAST APPLICATIONS

 

(Below 55°F / 12.8°C)

(Over 80 ft. / 24.38 m)

(Within 2 miles / 3.22 km)

 

 

 

 

Accumulator

Standard

Standard

Standard

 

 

 

 

Ball Bearing Fan Motor

Yes{

No

No

 

 

 

 

Compressor Start Assist Capacitor and

Yes

Yes

No

Relay

 

 

 

 

 

 

 

Crankcase Heater

Yes

Yes

No

 

 

 

 

Evaporator Freeze Thermostat

Yes

No

No

 

 

 

 

Hard Shutoff TXV

Yes

Yes

Yes

 

 

 

 

Isolation Relay

Yes

No

No

 

 

 

 

Liquid Line Solenoid Valve

No

See Long---Line Application

No

Guideline

 

 

 

 

 

 

 

Motor MasterControl or

Yes

No

No

Low Ambient Switch

 

 

 

 

 

 

 

Support Feet

Recommended

No

Recommended

* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline Application Guideline.

{ Additional requirement for Low---Ambient Controller (full modulation feature) MotorMasterr Control.

223A

Accessory Description and Usage (Listed Alphabetically)

1. Ball-Bearing Fan Motor

A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.

Usage Guideline:

Required on all units when using MotorMasterr

2. Compressor Start Assist - Capacitor and Relay

Start capacitor and relay gives a ”hard” boost to compressor motor at each start up.

Low ambient cooling

Suggested for all compressors in areas with a history of low voltage problems.

3. Compressor Start Assist — PTC Type

Solid state electrical device which gives a ”soft” boost to the compressor at each start-up.

Usage Guideline:

Suggested in installations with marginal power supply.

Usage Guideline:

Required for reciprocating compressors in the following applications:

Long line

Low ambient cooling

Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil

Required for single-phase scroll compressors in the following applications:

Long line

4. Crankcase Heater

An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging.

Usage Guideline:

Required in low ambient cooling applications. Required in long line applications.

Suggested in all commercial applications.

5

Page 5
Image 5
Bryant 223A manual Accessory Thermostats, Php, Nhp

223A specifications

The Bryant 223A is a cutting-edge air conditioning unit that epitomizes modern cooling technology. Designed for both residential and commercial applications, this model stands out for its efficiency, reliability, and user-friendly features. One of the most significant aspects of the Bryant 223A is its energy efficiency, boasting a Seasonal Energy Efficiency Ratio (SEER) rating of up to 16. This high rating means lower energy consumption, translating into reduced utility bills for homeowners and businesses alike.

One prominent feature of the Bryant 223A is its environmentally friendly design. It utilizes Puron refrigerant, which has zero ozone-depleting potential, making it a responsible choice for those looking to minimize their environmental footprint. In addition to being eco-conscious, the unit is equipped with a variable-speed compressor, allowing for improved humidity control and enhanced comfort levels. This technology enables the system to adjust its cooling output based on the current indoor conditions, resulting in more consistent temperatures and quieter operation.

Another noteworthy characteristic of the Bryant 223A is its robust construction. The cabinet is designed with galvanized steel, offering durability and resistance to corrosion. This resilience ensures that the unit can withstand the rigors of various weather conditions, contributing to its longevity. Moreover, the unit features an innovative design that minimizes noise levels, ensuring that it operates quietly without disturbing daily activities.

Ease of installation is yet another advantage of the Bryant 223A. The unit comes with a compact design, allowing for straightforward placement in a variety of settings. Additionally, its integration with modern smart thermostats provides users with enhanced control over their indoor climate. This feature enables homeowners to monitor and adjust their air conditioning settings remotely, adding convenience and efficiency to their energy management.

The Bryant 223A also incorporates advanced filtration systems, which significantly improve indoor air quality. Enhanced filters capture a wide range of airborne particles, including allergens, dust, and pollutants, making it an excellent choice for households with allergy sufferers. Overall, the Bryant 223A combines state-of-the-art technology, eco-friendly operation, and user-centric features, making it a leading choice in air conditioning solutions for a variety of environments.