Bryant 223A Electrical Data, A-Weightedsound Power, Charging Subcooling Txv-Typeexpansion Device

Models: 223A

1 58
Download 58 pages 61.98 Kb
Page 7
Image 7
ELECTRICAL DATA

ELECTRICAL DATA

 

 

 

 

 

 

 

 

MIN

MIN

MAX

MAX

MAX

UNIT SIZE---

 

OPER VOLTS*

COMPR

FAN

 

WIRE

WIRE

LENGTH

LENGTH

FUSE**

V/PH

 

 

 

 

 

MCA

SIZE†

SIZE†

ft (m)‡

ft (m)‡

or CKT

SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRK

 

 

MAX

MIN

LRA

RLA

FLA

 

60° C

75° C

60° C

75° C

 

 

 

AMPS

018---C

 

 

 

48.0

9.0

0.7

11.9

14

14

66 (20.1)

62 (18.9)

20

024---B

 

 

 

58.3

12.8

0.7

16.7

14

14

47 (14.3)

45 (13.7)

25

030---C

 

 

 

77.0

16.0

0.8

20.8

12

12

60 (18.3)

57 (17.4)

30

036---C

208/230/1

253

197

79.0

17.1

0.9

22.3

12

12

56 (17.1)

53 (16.2)

35

042---B

 

 

 

109.0

19.9

1.2

26.0

10

10

77 (23.5)

73 (22.3)

40

048---B

 

 

 

117.0

27.3

1.2

35.4

8

8

88 (26.8)

84 (25.6)

50

060---B

 

 

 

134.0

26.3

1.2

34.1

8

8

91 (27.7)

87 (26.5)

50

030---B

 

 

 

71.0

10.0

0.8

13.3

14

14

64 (19.5)

61 (18.6)

20

036---C

 

 

 

73.0

11.5

0.9

15.3

12

12

94 (28.7)

90 (27.4)

25

042---B

208/230/3

253

197

88.0

13.5

1.2

18.0

10

10

128 (39.0)

122 (37.2)

30

048---B

 

 

 

83.1

17.2

1.2

22.7

8

10

158 (48.2)

97 (29.6)

35

060---B

 

 

 

110.0

17.0

1.2

22.5

8

10

160 (48.8)

98 (29.9)

35

036---C

 

 

 

38.0

5.2

0.5

7.0

14

14

260 (79.2)

247 (75.3)

15

042---B

460/3

506

414

46.0

7.1

0.53

9.3

14

14

196 (59.7)

186 (56.7)

15

048---B

41.0

7.5

0.6

10.0

14

14

182 (55.5)

173 (52.7)

15

 

 

 

060---B

 

 

 

52.0

7.8

0.6

10.3

14

14

177 (54.0)

168 (51.2)

15

*Permissible limits of the voltage range at which the unit will operate satisfactorily

{If wire is applied at ambient greater than 30_C, consult table 310---16 of the NEC (ANSI/NFPA 70). The ampacity of non ---metallic---sheathed cable (NM), trade name ROMEX, shall be that of 60_C conditions, per the NEC (ANSI/NFPA 70) Article 336---26. If other than uncoated (no---plated), 60 or 75_C insula tion, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA70).

}Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time---Delay fuse.

FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA ---Minimum Circuit Amps RLA --- Rated Load Amps

NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.

Complies with 2001 requirements of ASHRAE Standards 90.1

A-WEIGHTED SOUND POWER

 

STANDARD

TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)

UNIT SIZE---SERIES (VOLTAGE)

RATING

 

 

 

 

 

 

 

125

250

500

1000

2000

4000

8000

 

(dBA)

 

 

 

 

 

 

 

 

 

018---C (N)

73

58.5

62.5

67.0

67.5

65.5

62.5

53.5

024---B (N)

72

54.5

63.0

66.5

66.0

64.0

60.5

51.5

030---C (N)

73

57.0

63.5

68.0

69.0

65.0

61.0

52.5

030---B (P)

72

53.0

60.5

66.0

67.5

64.5

61.5

53.0

036---C (N)

70

54.5

62.0

63.5

64.5

63.0

60.0

51.5

036---C (P, E)

73

57.0

63.5

68.0

69.0

65.0

61.0

52.5

042---B (N, P, E)

73

55.0

60.0

64.0

67.5

61.5

60.0

55.0

048---B (N, P, E)

74

57.5

64.5

67.5

69.5

66.5

61.0

53.0

060---B (N, P, E)

74

53.5

63.0

67.5

70.0

63.5

60.0

55.5

NOTE: Tested in accordance with ARI Standard 270---95 (not listed in ARI).

CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE)

UNIT SIZE---SERIES (VOLTAGE)

REQUIRED SUBCOOLING _F (_C)

018---C (N)

10 (5.6)

024---B (N)

12 (6.7)

030---C (N), B (P)

12 (6.7)

036---C (N, P,E)

10 (5.6)

042---B (N, P, E)

11 (6.1)

048---B (N, P, E)

11 (6.1)

060---B (N, P, E)

12 (6.7)

223A

7

Page 7
Image 7
Bryant 223A manual Electrical Data, A-Weightedsound Power, Charging Subcooling Txv-Typeexpansion Device