Bryant 313AAV/JAV manual Air Delivery - Cfm With Filter, Electrical Data, Supply, Volts

Models: 313AAV/JAV

1 12
Download 12 pages 34.67 Kb
Page 8
Image 8
AIR DELIVERY - CFM (WITH FILTER)*

313AAV/JAV

AIR DELIVERY - CFM (WITH FILTER)*

UNIT SIZE

RETURN---AIR

SPEED

 

 

 

EXTERNAL STATIC PRESSURE (in. wc)

 

 

 

SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

0.2

0.3

 

0.4

0.5

0.6

0.7

 

0.8

0.9

1

 

 

5

1185

1145

1115

 

1075

1035

980

905

 

820

720

580

 

Bottom or

4

920

880

835

 

800

755

720

680

 

645

605

540

024045

 

 

 

 

 

 

 

 

 

 

 

 

 

3

735

685

625

 

585

530

490

435

 

395

345

295

Side(s)

 

 

 

2

820

765

725

 

670

630

580

545

 

490

455

405

 

 

 

 

 

 

1

650

595

535

 

490

430

390

330

 

280

235

--- ---

 

 

5

1625

1585

1535

 

1495

1460

1415

1365

 

1295

1220

1125

 

Bottom or

4

1405

1360

1320

 

1280

1240

1195

1155

 

1115

1070

1030

048070

3

1240

1200

1155

 

1110

1065

1020

975

 

935

895

850

Side(s)

 

 

 

2

1190

1140

1095

 

1050

1000

955

915

 

870

830

790

 

 

 

 

 

 

1

1035

985

930

 

885

835

785

745

 

695

650

600

 

 

5

1845

1800

1755

 

1710

1665

1595

1500

 

1400

1275

1105

 

Bottom or

4

1590

1545

1500

 

1455

1410

1365

1315

 

1270

1180

1000

048090

 

 

 

 

 

 

 

 

 

 

 

 

 

3

1365

1320

1270

 

1215

1170

1125

1070

 

1025

955

900

Side(s)

 

 

 

2

1225

1160

1110

 

1060

1010

950

895

 

830

770

710

 

 

 

 

 

 

1

1100

1030

960

 

875

805

730

645

 

570

505

425

 

 

5

2255

2205

2150

 

2100

2040

1985

1920

 

1835

1735

1615

 

Bottom or

4

1600

1525

1465

 

1400

1335

1275

1210

 

1150

1080

1015

060110

3

1945

1890

1830

 

1770

1715

1655

1600

 

1545

1480

1430

Side(s)

 

 

 

2

1420

1340

1280

 

1200

1140

1065

1005

 

925

865

790

 

 

 

 

 

 

1

1280

1205

1140

 

1055

990

910

840

 

760

695

630

 

 

5

2295

2240

2185

 

2125

2070

2005

1925

 

1805

1670

1545

 

Bottom or

4

1725

1660

1605

 

1545

1460

1395

1340

 

1285

1230

1170

060135

 

 

 

 

 

 

 

 

 

 

 

 

 

3

1910

1865

1800

 

1745

1685

1610

1545

 

1485

1435

1380

Side(s)

 

 

 

2

1630

1575

1510

 

1435

1365

1300

1245

 

1185

1130

1065

 

 

 

 

 

 

1

1430

1355

1285

 

1200

1125

1075

1015

 

945

855

800

*A filter is required for each return ---air inlet. Airflow performance included 3/4---in. (19 mm) washable filter media such as contained in factory ---authorized ac-

cessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 in. wc available external static pressure.

 

 

--- --- Indicates unstable operating conditions.

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL DATA

313AAV/

VOLTS---

OPERATING VOLTAGE

MAXIMUM

MAXIMUM WIRE

MAXIMUM FUSE

MINIMUM

JAV UNIT

HERTZ---

RANGE*

OR CKT BKR

UNIT AMPS

LENGTH FT (M)}

WIRE GAGE

SIZE

PHASE

 

 

AMPS{

Maximum

Minimum

 

 

 

024045

115--- 60--- 1

127

104

8.1

34 (10)

15

14

048070

115--- 60--- 1

127

104

9.5

29 (9)

15

14

048090

115--- 60--- 1

127

104

10.3

27 (8)

15

14

060110

115--- 60--- 1

127

104

13.1

34 (10)

20

12

060135

115--- 60--- 1

127

104

13.1

34 (10)

20

12

*Permissible limits of the voltage range at which the unit operates satisfactorily. { Time ---delay type is recommended.

}Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.

8

Page 8
Image 8
Bryant 313AAV/JAV manual Air Delivery - Cfm With Filter, Electrical Data, Supply, Volts