SPECIFICATIONS
UNIT SIZE |
|
|
| 036080 |
| 048080 |
| 060080 | |
|
|
|
|
|
|
|
|
|
|
RATINGS AND PERFORMANCE |
|
|
|
|
|
|
|
| |
Input Btuh* |
|
|
| 80,000 |
| 80,000 |
| 80,000 | |
|
|
|
|
|
|
|
|
|
|
Output Capacity† ICS | Downflow |
| 75,000 |
| 75,000 |
| 75,000 | ||
|
|
|
|
|
|
|
|
|
|
AFUE%† |
|
|
|
|
|
|
|
| |
Nonweatherized ICS | Downflow |
| 90.0 |
| 90.0 |
| 90.0 | ||
|
|
|
|
|
|
|
|
|
|
Certified Temperature Rise Range °F |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
Certified External Static Pressure |
| Heating |
| 0.15 |
| 0.15 |
| 0.15 | |
|
|
|
|
|
|
|
|
|
|
|
|
| Cooling |
| 0.50 |
| 0.50 |
| 0.50 |
|
|
|
|
|
|
|
|
|
|
Airflow CFM‡ |
| Heating |
| 1190 |
| 1285 |
| 1785 | |
|
|
|
|
|
|
|
|
|
|
|
|
| Cooling |
| 1245 |
| 1525 |
| 1925 |
|
|
|
|
|
|
|
|
|
|
ELECTRICAL |
|
|
|
|
|
|
|
| |
Unit |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
Operating Voltage Range |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
Maximum Unit Amps |
|
|
| 7.6 |
| 10.0 |
| 14.1 | |
|
|
|
|
|
|
|
|
|
|
Unit Ampacity†† |
|
|
| 10.4 |
| 13.4 |
| 18.4 | |
|
|
|
|
|
|
|
|
|
|
Minimum Wire Size |
|
|
| 14 |
| 14 |
| 12 | |
|
|
|
|
|
|
|
|
|
|
Maximum Wire Length (Ft)‡‡ |
|
|
| 36 |
| 28 |
| 31 | |
|
|
|
|
|
|
|
|
|
|
Maximum Fuse Size or Ckt Bkr Amps |
|
|
|
|
|
|
|
| |
|
|
| 15 |
| 15 |
| 20 | ||
|
|
|
|
|
|
|
|
|
|
Transformer (24v) |
|
|
|
|
| 40va |
| ||
|
|
|
|
|
|
|
|
| |
External Control |
| Heating |
|
|
| 12va |
| ||
|
|
|
|
|
|
|
|
| |
Power Available |
| Cooling |
|
|
| 21va |
| ||
|
|
|
|
|
|
|
|
| |
Air Conditioning Blower Relay |
|
|
|
|
| Standard |
| ||
|
|
|
|
|
|
|
|
|
|
CONTROLS |
|
|
|
|
|
|
|
| |
Limit Control |
|
|
|
|
| SPST |
| ||
|
|
|
|
|
|
|
|
| |
Heating Blower Control (Off Delay) |
|
|
|
|
| Factory Set at 135 Sec |
| ||
|
|
|
|
|
|
|
|
| |
Burners (Monoport) |
|
|
| 4 |
| 4 |
| 4 | |
|
|
|
|
|
|
|
|
|
|
Gas Connection Size |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
GAS CONTROLS |
|
|
|
|
|
|
|
| |
Gas Valve (Redundant/Gas Convertible) | Manufacturer |
|
|
|
| ||||
|
|
|
|
|
| ||||
| Min Inlet Pressure (In. wc) |
|
| 4.5 (Natural Gas) 11.0 (Propane) |
| ||||
|
|
|
|
|
| ||||
| Max Inlet Pressure (In. wc) |
|
| 13.6 (Natural and Propane Gases) |
| ||||
|
|
|
|
|
|
|
|
| |
Ignition Device |
|
|
|
|
| Hot Surface |
| ||
|
|
|
|
|
|
|
|
|
|
BLOWER DATA |
|
|
|
|
|
|
|
| |
|
|
| 1/3 |
| 1/2 |
| 3/4 | ||
|
|
|
|
|
|
|
|
|
|
Motor Full Load Amps |
|
|
| 5.8 |
| 7.9 |
| 11.1 | |
|
|
|
|
|
|
|
|
|
|
RPM |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
Blower Wheel Diameter x Width (In.) |
|
|
| 10 x 7 |
| 11 x 8 |
| 11 x 10 | |
|
|
|
|
|
|
|
|
|
|
Filter Size |
|
|
|
| (1) 16 x 25 x 1 |
| (1) 20 x 25 x 1 | ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
| |||||
Downflow Base*** |
|
|
|
|
| KGASB0201ALL |
| ||
|
|
|
|
|
|
|
|
| |
Vent Termination Kit (Bracket Only for 2 Pipes) |
|
|
|
|
|
| |||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ||
Concentric Vent Termination Kit (Single Exit) |
|
|
|
|
|
| |||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ||
Condensate Freeze Protection Kit |
|
|
|
|
| KGAHT0101CFP |
| ||
|
|
|
|
|
|
|
|
| |
Electronic/Mechanical Air Cleaner |
|
|
|
|
| Model AIRA or 902B or MACA |
| ||
|
|
|
|
|
|
|
|
| |
Humidifier |
|
|
|
|
| Model HUM |
| ||
|
|
|
|
|
|
|
| ||
Heat/Energy Recovery Ventilator |
|
|
|
| Model VA3B, VB5B, VC5B, or VL3A |
| |||
|
|
|
|
|
|
|
|
|
|
*Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In Canada, derate
the unit 5% from 2000 to 4500 ft above sea level.
†Capacity and AFUE in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for top only
**Permissible voltage limits for proper furnace operation.
††Unit ampacity = 125% of largest component’s full load amps plus 100% of all other potential operating components (EAC, humidifier, etc.). ‡‡ Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
***Required for installation on combustible floors when no coil box is used, or when any coil box other than a Bryant CD5 or CK5 cased coil is used.