Bryant 351DAS warranty Specifications

Models: 351DAS

1 8
Download 8 pages 51.99 Kb
Page 4
Image 4

SPECIFICATIONS

UNIT SIZE

 

 

 

036080

 

048080

 

060080

 

 

 

 

 

 

 

 

 

 

RATINGS AND PERFORMANCE

 

 

 

 

 

 

 

 

Input Btuh*

 

 

 

80,000

 

80,000

 

80,000

 

 

 

 

 

 

 

 

 

 

Output Capacity† ICS

Downflow

 

75,000

 

75,000

 

75,000

 

 

 

 

 

 

 

 

 

 

AFUE%†

 

 

 

 

 

 

 

 

Nonweatherized ICS

Downflow

 

90.0

 

90.0

 

90.0

 

 

 

 

 

 

 

 

 

 

Certified Temperature Rise Range °F

 

 

 

40—70

 

30—60

 

20—50

 

 

 

 

 

 

 

 

 

 

Certified External Static Pressure

 

Heating

 

0.15

 

0.15

 

0.15

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

0.50

 

0.50

 

0.50

 

 

 

 

 

 

 

 

 

 

Airflow CFM‡

 

Heating

 

1190

 

1285

 

1785

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

1245

 

1525

 

1925

 

 

 

 

 

 

 

 

 

 

ELECTRICAL

 

 

 

 

 

 

 

 

Unit Volts—Hertz—Phase

 

 

 

 

 

115—60—1

 

 

 

 

 

 

 

 

 

 

Operating Voltage Range Min—Max**

 

 

 

 

 

104—127

 

 

 

 

 

 

 

 

 

 

Maximum Unit Amps

 

 

 

7.6

 

10.0

 

14.1

 

 

 

 

 

 

 

 

 

 

Unit Ampacity††

 

 

 

10.4

 

13.4

 

18.4

 

 

 

 

 

 

 

 

 

 

Minimum Wire Size

 

 

 

14

 

14

 

12

 

 

 

 

 

 

 

 

 

 

Maximum Wire Length (Ft)‡‡

 

 

 

36

 

28

 

31

 

 

 

 

 

 

 

 

 

 

Maximum Fuse Size or Ckt Bkr Amps

 

 

 

 

 

 

 

 

(Time-Delay Fuse Recommended)

 

 

 

15

 

15

 

20

 

 

 

 

 

 

 

 

 

 

Transformer (24v)

 

 

 

 

 

40va

 

 

 

 

 

 

 

 

 

 

External Control

 

Heating

 

 

 

12va

 

 

 

 

 

 

 

 

 

 

Power Available

 

Cooling

 

 

 

21va

 

 

 

 

 

 

 

 

 

 

Air Conditioning Blower Relay

 

 

 

 

 

Standard

 

 

 

 

 

 

 

 

 

 

 

CONTROLS

 

 

 

 

 

 

 

 

Limit Control

 

 

 

 

 

SPST

 

 

 

 

 

 

 

 

 

 

Heating Blower Control (Off Delay)

 

 

 

 

 

Factory Set at 135 Sec

 

 

 

 

 

 

 

 

 

 

Burners (Monoport)

 

 

 

4

 

4

 

4

 

 

 

 

 

 

 

 

 

 

Gas Connection Size

 

 

 

 

 

1/2-in. NPT

 

 

 

 

 

 

 

 

 

 

 

GAS CONTROLS

 

 

 

 

 

 

 

 

Gas Valve (Redundant/Gas Convertible)

Manufacturer

 

 

 

White-Rodgers

 

 

 

 

 

 

 

 

Min Inlet Pressure (In. wc)

 

 

4.5 (Natural Gas) 11.0 (Propane)

 

 

 

 

 

 

 

 

Max Inlet Pressure (In. wc)

 

 

13.6 (Natural and Propane Gases)

 

 

 

 

 

 

 

 

 

 

Ignition Device

 

 

 

 

 

Hot Surface

 

 

 

 

 

 

 

 

 

 

 

BLOWER DATA

 

 

 

 

 

 

 

 

Direct-Drive Motor HP (Permanent Split Capacitor)

 

 

 

1/3

 

1/2

 

3/4

 

 

 

 

 

 

 

 

 

 

Motor Full Load Amps

 

 

 

5.8

 

7.9

 

11.1

 

 

 

 

 

 

 

 

 

 

RPM (Nominal)—Speeds

 

 

 

 

 

1075—4

 

 

 

 

 

 

 

 

 

 

 

 

Blower Wheel Diameter x Width (In.)

 

 

 

10 x 7

 

11 x 8

 

11 x 10

 

 

 

 

 

 

 

 

 

 

Filter Size (In.)—Permanent Washable

 

 

 

 

(1) 16 x 25 x 1

 

(1) 20 x 25 x 1

 

 

 

 

 

 

 

 

 

FACTORY-AUTHORIZED AND LISTED, DEALER-INSTALLED OPTIONS

 

 

 

 

 

Downflow Base***

 

 

 

 

 

KGASB0201ALL

 

 

 

 

 

 

 

 

 

 

Vent Termination Kit (Bracket Only for 2 Pipes)

 

 

 

 

 

2-in.—KGAVT0101BRA

 

 

 

 

 

 

3-in.—KGAVT0201BRA

 

 

 

 

 

 

 

 

 

Concentric Vent Termination Kit (Single Exit)

 

 

 

 

 

2-in.—KGAVT0501CVT

 

 

 

 

 

 

3-in.—KGAVT0601CVT

 

 

 

 

 

 

 

 

 

Condensate Freeze Protection Kit

 

 

 

 

 

KGAHT0101CFP

 

 

 

 

 

 

 

 

 

 

Electronic/Mechanical Air Cleaner

 

 

 

 

 

Model AIRA or 902B or MACA

 

 

 

 

 

 

 

 

 

 

Humidifier

 

 

 

 

 

Model HUM

 

 

 

 

 

 

 

 

 

Heat/Energy Recovery Ventilator

 

 

 

 

Model VA3B, VB5B, VC5B, or VL3A

 

 

 

 

 

 

 

 

 

 

 

*Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In Canada, derate

the unit 5% from 2000 to 4500 ft above sea level.

Capacity and AFUE in accordance with U.S. Government DOE test procedures.

‡ Airflow shown is for top only return-air supply.

**Permissible voltage limits for proper furnace operation.

††Unit ampacity = 125% of largest component’s full load amps plus 100% of all other potential operating components (EAC, humidifier, etc.). ‡‡ Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.

***Required for installation on combustible floors when no coil box is used, or when any coil box other than a Bryant CD5 or CK5 cased coil is used. ICS—Isolated Combustion System

—4—