Bryant 604D--A installation instructions Interface Fan Board IFB, 604D-- --A

Models: 604D--A

1 52
Download 52 pages 10.87 Kb
Page 21
Image 21
Fig. 15 - Interface Fan Board (IFB)

ACCUMULATOR

COMPRESSOR

HP S

OUTDOOR COIL

INDOOR COIL

TXV in Metering

Position

LCS

LEGEND

Bypass

Position

HPS – High Pressure Switch

LCS – Loss of Charge Switch

Manual backgroundManual backgroundManual backgroundManual background Accurater®Metering De vice

Arrow indicates direction of flow

C03011

Fig. 14 - Typical Heat Pump Operation, Cooling Mode

 

 

 

HIGH

 

STD DEHUM

 

 

 

LOW

COM

 

 

 

 

QC5

 

 

 

 

QC4

QC3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KZ

 

 

 

 

 

 

KL

QCR

 

 

 

 

 

 

 

 

 

 

 

 

 

DCR

 

 

 

 

 

R13

C8

R11

Q1

 

 

C

CDM/C

07

09

0L0

08

 

 

 

 

ALO

 

 

D2

QC1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q3

 

 

AL2

24VAC/R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C9

C4

 

 

 

 

 

 

 

G1

RL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G2

 

3AMP

QIL

Z2

06

04

 

 

 

 

 

 

 

 

 

 

 

A7

R9

AB

A15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C0

F1

 

 

 

 

 

 

 

 

U1

 

 

Z1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C3

 

 

R4

RL4

D5

D3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JWZ

 

P3

 

 

R2

JW5

 

R3

R5

R6

 

 

 

 

 

 

 

 

 

 

 

P2

JW3

 

 

 

 

 

 

 

QCB

 

 

 

 

 

P4

 

 

 

 

 

 

 

 

 

 

 

 

SDL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

R

W2 Y

 

C

 

 

W3 W3 W2 W2 C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JW4

 

 

 

SSTZ-8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1

 

 

Y2

 

Y1

 

 

 

 

 

 

 

 

 

W3 W2

G

C

R

 

 

 

 

 

 

 

DH

Y

 

 

A09059

Fig. 15 - Interface Fan Board (IFB)

604D-- -- A

ACCUMULATOR

COMPRESSOR

OUTDOOR COIL

INDOOR COIL

TXV in Bypass

Position

LCS

HP S

Metering

Position

LEGEND

HPS – High Pressure Switch

LCS – Loss of Charge Switch

Manual backgroundManual backgroundManual backgroundManual background Accurater®Metering De vice

Arrow indicates direction of flow

C03012

Fig. 16 - Typical Heat Pump Operation, Heating Mode

21

Page 21
Image 21
Bryant 604D--A installation instructions Interface Fan Board IFB, 604D-- --A