Bryant 650A warranty SPECIFICATIONS Continued

Models: 650A

1 20
Download 20 pages 45.05 Kb
Page 5
Image 5

SPECIFICATIONS Continued

UNIT SIZE-SERIES

042-A.C

 

048-A,C

 

060-B,C

Operating Weight (Lb)

218

 

266

 

295

 

 

 

 

 

 

ELECTRICAL

 

 

 

 

 

Unit Volts—Hertz—Phase

 

 

208/230—60—1

 

 

 

 

 

 

 

 

Operating Voltage Range*

 

 

187—253

 

 

 

 

 

 

 

Compressor Rated Load Amps

21.1

 

20.5

 

27.6

 

 

 

 

 

 

Compressor Locked Rotor Amps

104.0

 

109.0

 

158.0

 

 

 

 

 

 

Condenser Fan Motor—Full Load Amps

1.1

 

1.4

 

1.4

 

 

 

 

 

 

Minimum Unit Ampacity for Wire Sizing

27.5

 

27.0

 

35.9

 

 

 

 

 

 

Minimum Wire Size (60°C Copper) (AWG)†

10

 

10

 

8

 

 

 

 

 

 

Minimum Wire Size (75°C Copper) (AWG)†

10

 

10

 

8

 

 

 

 

 

 

Maximum Wire Length (60°C) (Ft)‡

71

 

74

 

86

 

 

 

 

 

 

Maximum Wire Length (75°C) (Ft)‡

68

 

70

 

82

 

 

 

 

 

 

Maximum Branch Circuit Fuse Size**

40

 

40

 

60

 

 

 

 

 

 

COMPRESSOR & REFRIGERANT

 

 

 

 

 

Compressor Manufacturer

 

 

Copeland

 

 

 

 

 

 

 

 

Compressor Type

 

 

Scroll

 

 

 

 

 

 

 

 

Refrigerant Type

 

 

Puron

 

 

 

 

 

 

 

Refrigerant Amount (Lb)††

8.63

 

13.25

 

13.25

 

 

 

 

 

 

OUTDOOR COIL & FAN

 

 

 

 

 

Coil Face Area (Sq Ft)

12.12

 

18.18

 

18.18

 

 

 

 

 

 

Fins per In.—Rows—Circuits

20—2—3

 

20—2—4

 

20—2—5

 

 

 

 

 

 

Fan Motor—HP & RPM

1/5 and 825

 

1/4 and 1100

 

1/4 and 1100

 

 

 

 

 

 

Rated Airflow (CFM)

2800

 

3300

 

3300

 

 

 

 

 

 

OPTIONAL EQUIPMENT

 

 

 

 

 

Support Feet—4 In. (4)

 

 

KSASF0101AAA

 

 

 

 

 

 

 

 

Snow Stand—18 In.

 

 

KHASS0206MPK

 

 

Time Delay Relay

 

 

KAATD0101TDR

 

 

 

 

 

 

 

 

Interface Control (Energy Minder)‡‡

 

 

KHAIC0101AAA

 

 

 

 

 

 

 

 

Service Alarm***

 

 

KHASA0101AAA

 

 

 

 

 

 

 

 

Outdoor Thermostat

 

 

KHAOT0301FST

 

 

 

 

 

 

 

 

Secondary Outdoor Thermostat

 

 

KHAOT0201SEC

 

 

 

 

 

 

Crankcase Heater

KAACH1201AAA

 

 

Standard

 

 

 

 

Start Assist—Capacitor/Relay Type

KSAHS1501AAA

 

KSAHS1601AAA

 

 

 

 

 

 

Start Assist—PTC Type

Standard

 

 

KAACS0201PTC

 

 

 

 

 

Bi-Flow TXV (Hard Shutoff)

KSATX0301HSZ

 

KSATX0401HSZ

 

KSATX0501HSZ

 

 

 

 

 

 

Filter Drier (Suction Line)

 

 

KH45LG141 (RCD)

 

 

 

 

 

 

 

 

Evaporator Freeze Thermostat†††

 

 

KAAFT0101AAA

 

 

 

 

 

 

 

 

Isolation Relay†††

 

 

KHAIR0101AAA

 

 

 

 

 

 

 

 

Liquid-Line Solenoid Valve (LSV)

 

 

KHALS0401LLS

 

 

 

 

 

 

 

 

Low-Ambient Pressure Switch

 

 

KSALA0301410

 

 

* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.

If other than uncoated (non-plated), 60°C or 75°C (140° or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).

If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26.

Length shown is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2 percent. ** Time-delay fuse or circuit breaker.

††The factory refrigerant charge is for 15 ft of interconnecting tubing. For tubing lengths other than 15 ft, refer to the Residential Split-Systems Long-Line Application Guideline and Service Manual for Residential Split-System Air Conditioners and Heat Pumps using Puron (R-410A).

‡‡ Outdoor thermostat required.

***For indicator function, thermostat specified must be used and wired according to service alarm Installation Instructions.

††† Use with low-ambient pressure switch.

NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.